Hoshizaki Ice Bank Beer System Скачать руководство пользователя страница 12

Ice Bank Beer System Manual 

 

 

www.lancerbeverage.com 

Page 12 of 17

 

Hoshizaki Lancer reserve the right to change specifications without notice. 

Part No:  68000213 

Images are for illustration purposes only as product may vary. 

No 072-2  –  26 May 2020

 

8.  Certificate of Warranty 

It is the policy of Hoshizaki to provide to its current customers, warranty for all equipment supplied and 
installation work performed within a specified period. 

Parts and Equipment 

Hoshizaki Lancer provides a warranty period of twelve (12) months from the date of original invoice for all 
manufactured parts and the associated labour. Repair or replace of defective parts will be at the sole discretion 
of Hoshizaki Lancer. 
Changeover parts will be invoiced to the customer at the customers normal purchase cost and upon return of 
the warranty item and validation of the claim, the invoice will be credited. 

Installations 

Hoshizaki Lancer provides a warranty period of twelve (12) months from the date of final invoice for 
workmanship after the completion of any installation work, provided the parts and labour are completed by 
Hoshizaki Lancer or its sub-contractor.  

Labour 

Hoshizaki Lancer will not normally cover any labour costs associated with a warranty claim. Subject to the 
approval of the Divisional Sales Manager, Hoshizaki Lancer may choose to reimburse the customer for some or 
all labour costs associated with a warranty claim. Any claim for labour costs must be authorized by Hoshizaki 
Lancer prior to the work being undertaken 

Exclusions 

Hoshizaki Lancer will not accept any liability or cost associated with any consequential losses (such as loss of 
syrup or beer), loss of profit or damage to property as a result of faulty product. 
Warranty shall not apply: 
a.  If in the opinion of Hoshizaki Lancer, the equipment has been used in a situation the equipment has not 

been designed for; 

b.  If in the opinion of Hoshizaki Lancer, the equipment has been subject to abuse, negligence or accident; 
c.  If connected to improper, inadequate or faulty power, water or drainage service or operated using 

incorrect, insufficient or contaminated lubricants, coolants, refrigerants or additives; 

d.  Where the product is installed, maintained or operated otherwise than in accordance with the instructions 

supplied by Hoshizaki Lancer; 

e.  Where the product has been damaged by foreign objects; 
f. 

Where the product has been serviced, repaired, altered or moved otherwise than by Hoshizaki Lancer or 
its nominees or using other than Hoshizaki Lancer approved replacement parts. 

Содержание Ice Bank Beer System

Страница 1: ...www lancerbeverage com Ice bank Beer System Operation Manual...

Страница 2: ...ouring Heady 5 Beer is not Pouring 5 Beer is Pouring Flat 5 Beer is Pouring Slow 5 Loss of Condensation on the Founts 6 Ice bank Tank Temperature Increase 6 Using Excessive Amounts of Gas 6 4 Cleaning...

Страница 3: ...keg is tapped by connecting the coupler to the keg The coupler is then engaged Beer is distributed to the correct tap CO2 Beverage Gas is supplied to each keg as the energy to move the beer from the...

Страница 4: ...nd is to provide a blanket of CO2 on top of the beer to ensure balance of correct CO2 is maintained in the beer This is crucial For Nitrogenous Beers and Stouts a separate Regulator will supply a Stou...

Страница 5: ...cool room to see if the coupler handle is fully engaged Damaged handle pivots sometimes prevent this Gas System turned OFF check if the bottle is turned on and ensure there is CO2 in the bottle Beer F...

Страница 6: ...s of Gas Gas leak on system Check over gas system as per Weekly Checks Gas Leaks Higher than usual turnover of kegs this is to be expected 4 Cleaning the System Regular cleaning of the whole beer syst...

Страница 7: ...ly rinse a washout canister and fill with potable water A 5L washout canister is available from Hoshizaki Lancer Before opening vent the canister by pulling the relief valve ring Turn the keg coupler...

Страница 8: ...e valve shaft from the beer tap Fig 3 Clean the beer tap and valve by using a neutral dishwashing detergent and the accessory cleaning brush Rinse the beer tap thoroughly with clean water Assemble the...

Страница 9: ...e from the evaporator use only warm water so as not to damage the evaporator or the water bath tank empty the water with a suction pump or draining pipe Clean the stainless steel coils and the evapora...

Страница 10: ...he gauge needle 5 If the needle has held its position there is no leak in the isolated gas system from the cylinder through the gas regulators to the gas valves 6 If the needle drops away from the mar...

Страница 11: ...on Stout mix is a 70 N2 30 CO2 mix required to dispense Nitrogenised Beverages Cylinder Pressure The pressure in a cylinder of C02 is approximately 5 6 000kPa 800psi The pressure in a cylinder of mixe...

Страница 12: ...not normally cover any labour costs associated with a warranty claim Subject to the approval of the Divisional Sales Manager Hoshizaki Lancer may choose to reimburse the customer for some or all labo...

Страница 13: ...CELLAR EQUIPMENT All cellar equipment greased leads keg couplers adaptors All cellar equipment tightened leads keg couplers adaptors Each Beer Line tested for correct position and leaks Water Bath fu...

Страница 14: ...0 10 Commissioning Sheet OUTLET INSTALLED BY COMMISSIONED BY Flow Rate For 285ml Glass Of Beer Beer Temperature 3rd glass Gas System Settings Regulator 1 Miscellaneous Training Manual Given Installer_...

Страница 15: ...ation and Use of Inert Gases for Beverage Dispense AS5034 Lancer Technician Name Date of Compliance Venue Name Suburb Description of work Scope of Compliance New Beer Gas Distribution System New Beer...

Страница 16: ...in use x 2 Oxygen Level vr vg vr x21 Oxygen Level AS5034 Onsite Risk Assessment To be completed by competent person Site Contact Name Site Contact Number Venue Name Customer No Venue Address Location...

Страница 17: ...reme Low Moderate High Extreme Low Low Moderate High Low Low Low Moderate Residual Risk Rating Comments please note any site specific comments or discussions held with site contact Please retain recor...