23
IV. SERVICE DIAGNOSIS
1. NO ICE PRODUCTION
1) Broken or loose connection.
1) “OFF” position.
1) Blown out.
1) Shut-off Valve closed.
2) Water supply “OFF”
1) Clogged.
1) Bad contacts (Terminal Nos.
4 and 6).
2) Coil winding opened.
3) Loose connections.
1) Bad contacts.
2) Coil winding opened.
3) Loose connections.
4) Defective.
1) Motor winding opened or
grounded.
1) Bad contacts (X2 Relay).
2) X2 Relay coil winding
opened.
3) Loose connections.
1) Bad contacts.
1) Bad contacts.
1) Defective.
1) Motor winding opened.
1) Bad contacts (X1 Relay).
1) Bad contacts.
2) Coil winding opened.
3) Loose connections.
1) Bad Contact.
1) Defective
[1] The ice
dispenser will
not start.
[2] Water Valve
operates, but
no ice is
produced.
[3] Compressor
will not start.
[4] Gear Motor
will not start.
a) Power Supply Cord
b) Power Switch (on
left bottom of Front
Panel)
c) Fuse
1A (Control Box)
a) Water Supply Line
b) Water Valve
c) Water Control Relay
d) Timer
a) Compressor
b) Timer
c) Motor Protector
d) Starter
e) Starting or Running
Capacitor
a) Gear Motor
b) Timer
c) Protect Relay
d) Protector
e) Capacitor
1) Check for continuity and
replace.
1) Move to “ON” position.
1) Check for short-circuit and
replace.
1) Open.
2) Check and get recom-
mended pressure.
1) Clean.
1) Check for continuity and
replace.
2) Replace.
3) Tighten.
1) Check for continuity and
replace.
2) Replace.
3) Tighten.
4) Replace.
1) Replace.
1) Check for continuity and
replace.
2) Replace.
3) Tighten.
1) Check for continuity and
replace.
1) Check for continuity and
replace.
1) Replace.
1) Replace.
1) Check for continuity and
replace.
1) Check for continuity and
replace.
2) Replace.
3) Tighten.
1) Check for continuity and
replace.
1) Replace.
PROBLEM
POSSIBLE CAUSE
REMEDY
A2AAA0269806
Содержание DCM-240BAF
Страница 8: ...8 A2AAA0269804 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERANT CIRCUIT...
Страница 9: ...9 A2AAA0269804 2 WIRING DIAGRAM...
Страница 11: ...11 A2AAA0269806 RESERVOIR FILLS UP GEAR MOTOR TURNS ON...
Страница 12: ...12 A2AAA0269806 COMPRESSOR STARTS 60 SEC AFTER GEAR MOTOR...
Страница 13: ...13 A2AAA0269806 ICE MAKING CONTINUES...
Страница 14: ...14 A2AAA0269806 BIN CONTROL SWITCH TRIPPED COMPRESSOR STOPS 90 SEC LATER...
Страница 15: ...15 A2AAA0269806 GEAR MOTOR STOPS 60 SEC AFTER COMPRESSOR...
Страница 16: ...16 A2AAA0269806 DISPENSE ICE BIN CONTROL STILL TRIPPED...
Страница 17: ...17 A2AAA0269806 DISPENSE WATER BIN CONTROL STILL TRIPPED...
Страница 19: ...19 A2AAA0269806 FLUSH SWITCH ACTIVATED...
Страница 20: ...20 A2AAA0269806 FLUSH VALVE ACTIVATED WITH TIMER...
Страница 21: ...21 A2AAA0269806 AGITATION TIMER ACTIVATES GEAR MOTOR...