28
A2AAA0260312
V. REMOVAL AND REPLACEMENT OF COMPONENTS
IMPORTANT
Ensure all components, fasteners and thumbscrews are securely in place
after the equipment is serviced.
IMPORTANT
1. The Polyol Ester (POE) oils used in R-404A units can absorb moisture
quickly. Therefore it is important to prevent moisture from entering the
system when replacing or servicing parts.
2. Always install a new filter drier every time the sealed refrigeration system is
opened.
3. Do not leave the system open for longer than 5 minutes when
replacing or servicing parts.
1. SERVICE FOR REFRIGERANT LINES
[a] REFRIGERANT RECOVERY
The icemaker unit is provided with two Refrigerant Access Valves–one on the low-side and
one on the high-side line. Using proper refrigerant practices, recover the refrigerant from
these two Access Valves and store it in an approved container. Do not discharge the
refrigerant into the atmosphere.
[b] EVACUATION AND RECHARGE [R-404A]
1) Attach Charging Hoses, a Service Manifold and a Vacuum Pump to the system. Be
sure to connect charging hoses to both High and Low -side Access Valves.
IMPORTANT
The vacuum level and Vacuum Pump may be the same as those for
current refrigerants. However, the rubber hose and gauge manifold to be used
for evacuation and refrigerant charge should be exclusively for POE oils.
2) Turn on the Vacuum Pump. Never allow the oil in the Vacuum Pump to flow
backward.
3) Allow the Vacuum Pump to pull down to a 29.9" Hg vacuum. Evacuating period
depends on pump capacity.
Содержание DCM-240BAF
Страница 8: ...8 A2AAA0269804 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERANT CIRCUIT...
Страница 9: ...9 A2AAA0269804 2 WIRING DIAGRAM...
Страница 11: ...11 A2AAA0269806 RESERVOIR FILLS UP GEAR MOTOR TURNS ON...
Страница 12: ...12 A2AAA0269806 COMPRESSOR STARTS 60 SEC AFTER GEAR MOTOR...
Страница 13: ...13 A2AAA0269806 ICE MAKING CONTINUES...
Страница 14: ...14 A2AAA0269806 BIN CONTROL SWITCH TRIPPED COMPRESSOR STOPS 90 SEC LATER...
Страница 15: ...15 A2AAA0269806 GEAR MOTOR STOPS 60 SEC AFTER COMPRESSOR...
Страница 16: ...16 A2AAA0269806 DISPENSE ICE BIN CONTROL STILL TRIPPED...
Страница 17: ...17 A2AAA0269806 DISPENSE WATER BIN CONTROL STILL TRIPPED...
Страница 19: ...19 A2AAA0269806 FLUSH SWITCH ACTIVATED...
Страница 20: ...20 A2AAA0269806 FLUSH VALVE ACTIVATED WITH TIMER...
Страница 21: ...21 A2AAA0269806 AGITATION TIMER ACTIVATES GEAR MOTOR...
Страница 45: ...45 Fig 6 Fig 5 Middle Front Panel Thumbscrew Spout A Spout B A2AAA0269806...