211
SmartStacker User's Manual
6-2
If an Error Code Is Displayed on SmartStacker
If an error occurs, an error code will appear on the Error screen. See the tables below and correct the cause
of the error. The Error screen will be cleared when the OK button is pressed.
Code
Description and Causes
Solutions
Jam, Emergency Stop: 100-999
1st Regist Unit/1st Process Unit: 100-
100
1st regist unit Emergency Stop
The S100 Emergency Stop button is pressed.
Release the Emergency Stop button.
101
1st regist unit cover open
The 1st regist unit cover (S101) is open.
Close the cover.
102
1st process unit top cover open
The 1st process unit top cover (S102) is open.
103
1st process unit right cover open
The 1st process unit right cover (S103) is open.
104
1st process unit left cover open
The 1st process unit left cover (S104) is open.
108
Cycle time error
The sheet interval is too short. B110 turned on
twice within the specified time.
Make the sufficient feed interval by reducing the
production speed.
Also, check the B110 sensor is not dirty. (See
page 370 for the cleaning instruction.)
109
Sheet remains at ultrasonic sensor or signal
wiring disconnected
Sheets may be jammed at the B912 ultrasonic
sensor of the feeder. Or, the wiring for the sheet
exit signal is disconnected.
Remove the sheet jammed at the sheet feeder.
110
Sheet has not arrived at 1st regist unit entrance
sensor
The B110 was not turned on within the specified
time.
Remove the sheet jammed at the sheet feeder.
111
Sheet remains at 1st regist unit entrance sensor
The B110 has remained on for longer than the
specified time.
Remove the sheet jammed at the sheet feeder.
If this error code appeared even though the sheet
is not jammed, check the B110 sensor is not dirty.
(See page 370 for the cleaning instruction.)
112
Too many sheets at 1st regist unit
The number of sheets between B110 and B120
exceeded the specified number.
Remove the sheets which are jammed. Also,
check the B110 sensor is not dirty. (See page
370 for the cleaning instruction.)
120
Sheet has not arrived at 1st process unit entrance
sensor
The B120 was not turned on within the specified
time.
Remove the sheet jammed at the 1st regist unit.
If this error code appeared even though the sheet
is not jammed, check the B110 sensor is not dirty.
(See page 370 for the cleaning instruction.)
Содержание SmartStacker
Страница 106: ...This page is intentionally left blank ...
Страница 110: ...110 SmartStacker User s Manual Daily Safety Check Lift the cover pressing the hooks Hooks ...
Страница 146: ...This page is intentionally left blank ...
Страница 170: ...This page is intentionally left blank ...
Страница 206: ...This page is intentionally left blank ...
Страница 207: ...6 This chapter explains some possible problems and suggests some solutions 6 Troubleshooting ...
Страница 367: ...367 SmartStacker User s Manual If a Jam Occurs B2 Stacker Option 10606650901C1 Feeder Option ...
Страница 368: ...This page is intentionally left blank ...
Страница 376: ...376 SmartStacker User s Manual SmartStacker Merge Conveyor Merge Stacker B2 Stacker Optional ...
Страница 379: ...379 SmartStacker User s Manual SmartStacker B2 Stacker Optional Vacuum Belt ...
Страница 381: ...381 SmartStacker User s Manual SmartStacker Merge Conveyor ...
Страница 390: ...This page is intentionally left blank ...
Страница 391: ...6 8 This chapter lists the specifications for this machine 8 Appendix ...
Страница 411: ...This page is intentionally left blank ...
Страница 412: ...Manufacturer Phone 81 75 934 6700 Fax 81 75 934 6708 www horizon co jp ...