234
SmartStacker User's Manual
If an Error Code Is Displayed on SmartStacker
Code
Description and Causes
Solutions
1503
Deposition of K503 Emergency Stop Contactor 1
Even though the S500 Emergency Stop button is
pressed, the contact points of K503 are closed.
Check the following in order:
- The Emergency Stop button is not pressed.
If this error occurs frequently, call your local
dealer.
1504
Deposition of K504 Emergency Stop Contactor 2
Even though the S500 Emergency Stop button
is pressed or the contact points of S501/S502/
S503/S504/S505 are open, the contact points of
K504 are closed.
Check the following in order:
- All the covers are properly closed.
- The Emergency Stop button is not pressed.
If this error occurs frequently, call your local
dealer.
1505
K501 Interlock Contactor 1 Function Error
Though the interlock circuit is closed (=all the
covers close), the contact points for terminals 21
and 22 on K501 are open.
Check the following in order:
- The Emergency stop button is not pressed.
- All the covers are properly closed.
If this error occurs frequently, call your local
dealer.
1506
K502 Interlock Contactor 2 Function Error
Though the interlock circuit is closed (=all the
covers close and S400 Emergency Stop button is
not pressed), the contact points for terminals 21
and 22 on K502 are open.
Check the following in order:
- The Emergency stop button is not pressed.
- All the covers are properly closed.
If this error occurs frequently, call your local
dealer.
1511
S520 Stack Table Overlimit Switch Error (Rear)
The S520 stack table overlimit rear switch was
activated.
The vacuum belt unit is lifted up.
Remove an obstacle which pushes the vacuum
belts unit up.
1512
S521 Stack Table Overlimit Switch Error (Front)
The S521 stack table overlimit front switch was
activated.
The vacuum belt unit is lifted up.
Remove an obstacle which pushes the vacuum
belts unit up.
1513
S541 Stack Table Upper Limit Error
The S541 stack table upper limit switch was
activated.
If this error occurs frequently, call your local
dealer.
1514
S542 Stack Table Lower Limit Error
The S541 stack table lower limit switch was
activated.
1515
Stack Table Up/Down Timeout Error
The moving stack table is not detected within
the specified time by sensor B521, B522, B523,
B524, B543 or B544.
In case that the sheet is detected by the sensor
B524 even when the stack table is lowered, this
error occurs. Check that no sheet caught with
stopper.
1525
B2 Stacker Count Over Error
The number of the stacked sheets exceeded the
preset number.
Remove the stacks at the delivery section. If
this error occurs frequently, check the B520
is not dirty. (See page 374 for the cleaning
instruction.)
Содержание SmartStacker
Страница 106: ...This page is intentionally left blank ...
Страница 110: ...110 SmartStacker User s Manual Daily Safety Check Lift the cover pressing the hooks Hooks ...
Страница 146: ...This page is intentionally left blank ...
Страница 170: ...This page is intentionally left blank ...
Страница 206: ...This page is intentionally left blank ...
Страница 207: ...6 This chapter explains some possible problems and suggests some solutions 6 Troubleshooting ...
Страница 367: ...367 SmartStacker User s Manual If a Jam Occurs B2 Stacker Option 10606650901C1 Feeder Option ...
Страница 368: ...This page is intentionally left blank ...
Страница 376: ...376 SmartStacker User s Manual SmartStacker Merge Conveyor Merge Stacker B2 Stacker Optional ...
Страница 379: ...379 SmartStacker User s Manual SmartStacker B2 Stacker Optional Vacuum Belt ...
Страница 381: ...381 SmartStacker User s Manual SmartStacker Merge Conveyor ...
Страница 390: ...This page is intentionally left blank ...
Страница 391: ...6 8 This chapter lists the specifications for this machine 8 Appendix ...
Страница 411: ...This page is intentionally left blank ...
Страница 412: ...Manufacturer Phone 81 75 934 6700 Fax 81 75 934 6708 www horizon co jp ...