243
SmartStacker User's Manual
If an Error Code Is Displayed on SmartStacker
Code
Description and Causes
Solutions
3131
Inverter alarm
Motor overload shut-off
(Inverter display: E.THM)
The electronic thermal alarm built into the
inverter has detected an overload of the motor of
overheating in the motor due to poor cooling, and
has stopped the output from the inverter.
If this error occurs frequently, call your local
dealer.
3140
Inverter alarm
Fin overheat
(Inverter display: E.FIN)
The cooling fins on the inverter have overheated,
so the temperature sensor has stopped the
output from the inverter.
Turn off the power. Wait about 30 minutes and
turn on the power again. If this error occurs
frequently, call your local dealer.
3152
Inverter alarm
Input phase failure
(Inverter display: E.ILF)
A phase failure has occurred in one of the three
input phases (R, S and T) to the inverter, or there
was a big difference in voltage between the input
phases. This has stopped the output from the
inverter.
If this error occurs frequently, call your local
dealer.
3160
Inverter alarm
Stall prevention
(Inverter display: E.OLT)
The operating frequency has been dropped to “0”
by the stall preventer function.
Additional Information
Operation of stall preventer: This function
prevents the inverter from tripping if the
acceleration/deceleration time is too short or if
the inverter is overloaded during constant-speed
operation.
3170
Inverter alarm
Brake circuit problem
(Inverter display: E.BE)
The brake transistor has failed due to excessive
regenerative energy from the motor. The output
from the inverter has been stopped.
Turn off the power. Wait about 30 minutes and
turn on the power again. If this error occurs
frequently, call your local dealer.
Содержание SmartStacker
Страница 106: ...This page is intentionally left blank ...
Страница 110: ...110 SmartStacker User s Manual Daily Safety Check Lift the cover pressing the hooks Hooks ...
Страница 146: ...This page is intentionally left blank ...
Страница 170: ...This page is intentionally left blank ...
Страница 206: ...This page is intentionally left blank ...
Страница 207: ...6 This chapter explains some possible problems and suggests some solutions 6 Troubleshooting ...
Страница 367: ...367 SmartStacker User s Manual If a Jam Occurs B2 Stacker Option 10606650901C1 Feeder Option ...
Страница 368: ...This page is intentionally left blank ...
Страница 376: ...376 SmartStacker User s Manual SmartStacker Merge Conveyor Merge Stacker B2 Stacker Optional ...
Страница 379: ...379 SmartStacker User s Manual SmartStacker B2 Stacker Optional Vacuum Belt ...
Страница 381: ...381 SmartStacker User s Manual SmartStacker Merge Conveyor ...
Страница 390: ...This page is intentionally left blank ...
Страница 391: ...6 8 This chapter lists the specifications for this machine 8 Appendix ...
Страница 411: ...This page is intentionally left blank ...
Страница 412: ...Manufacturer Phone 81 75 934 6700 Fax 81 75 934 6708 www horizon co jp ...