Time Zone Name
This option controls the time zone name.
•
String length: 10 characters
This setting is used as "display name" in the "ALTERNATE_TIME_OFFSET_INDICATOR
TLV". The other parameters that are needed by this TLV are taken from the system settings.
8.3.4.3 PTP Advanced Settings
The "PTP Advanced Settings" window supplies settings for the communication of the PTP
service. These settings can be only changed, if the "PTP Profile" is set to "None" in the "PTP
Configuration" window.
PTP Transport
This setting determines the network protocol that is used by the PTP service.
Possible choices: "Ethernet / P2P", "Ethernet / E2E" und "IPv4 / E2E"
PTP sync interval (2^x sec)
This setting determines the sending interval of SYNC messages of the PTP service.
The sending interval is calculated in the following way:
•
x … selected value in the WebGUI
•
Sending interval = 2
x
•
Value-range: -7 to 6