HTTP/HTTPS
W
EB
GUI
–
W
EB
B
ROWSER
C
ONFIGURATION
I
NTERFACE
8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00
134 / 178
hopf
Elektronik GmbH
Nottebohmstr. 41
• D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
Databits
Possible settings are:
•
8
for 8 databits
•
7
for 7 databits
Parity
Possible settings are:
•
No Parity
•
Even Parity
•
Odd Parity
Stopbits
Possible settings are:
•
1
for 1 stopbit
•
2
for 2 stopbits
8.3.8.5.2 Timebase
Timebase
Local Time
Standard Time
UTC Time
In general the local time is set as the base. This time leaps forward/back 1 hour every daylight
saving time changeover. The standard or UTC time must be selected as the base if automatic
daylight saving time changeover shall be suppressed.
When setting standard time (winter time), the time offset to local summer time is minus 1 hour.
Standard time runs continuously (without time leap) throughout the whole year.
When setting UTC, the world time (formerly GMT) is used as the time base. This time base
also runs continuously (without time leap) throughout the whole year.
8.3.8.5.3 Output scheme
The output scheme for the transmission must be selected here:
•
Without second forerun / immediate control character
•
With second forerun / immediate control character
•
With second forerun / control character every second
•
With second forerun / control character delayed every second
8.3.8.5.4 Transmission Time
•
Every Second
•
EveryMinute
•
Every Hour
•
Remote