HTTP/HTTPS
W
EB
GUI
–
W
EB
B
ROWSER
C
ONFIGURATION
I
NTERFACE
8030HEPTA/GPS GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface - V04.00
125 / 178
hopf
Elektronik GmbH
Nottebohmstr. 41
• D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
Range of Sync.-Status
The synchronization status is represented from the bottom of the following table (INVA) up
with increasing quality.
Synchronisation Status
SYNC
Time synchr quartz control started/running
SYOF
Time synchr SyncOFF running
SYSI
Time synchronized as simulation mode
(with no actual GPS reception)
QUON
Quartz/crystal time + SyncON running
QUEX
Quartz/crystal time (in freewheel after synchronization
failure
Board was already synchronized)
QUSE
Quartz/crystal time after reset or manually set
INVA
Invalid time
Value range TimeOFF timer = 0 to 65635min.
8.3.8.1.3 Status of the Signal Output
The status of the output is stated via a display element with the following color and text indi-
cations:
GREEN
OUTPUT active
There is a signal output
YELLOW
OUTPUT
+ TimeOFF active
There is a signal output
for the duration of the TimeOFF Timer
RED
OUTPUT blocked
There is
no
signal output
8.3.8.1.4 Output inverted
All outputs stated in the system manuals of the according devices are related to the DEFAULT
setting: Output not inverted.
If nevertheless the inverting of the output signal has to be configured the "Output inverted"
checkbox has to be enabled.
8.3.8.1.5 Special Configuration
If used, the correct settings are described in the additional system manual of the customer-
specific device.
Otherwise for S1-S8 the DEFAULT-setting (all checkboxes disabled) should not be changed
due to compatibility reasons.