8.3.8.5.6.6.3 Status
The characters 28-31 in the data string SINEC H1 Extended tell the synchronization status of
the Sync Module 8024GPS.
The characters mean the following:
character no. 28 = "#"
no synchronisation after reset, time invalid
"synchronization status code: INVA"
" " (space) synchronisation after reset, clock in crystal operation
"synchronization status code:
QUSE / QUEX / QUON / SYOF / SYNC"
character no. 29 = "*"
time from internal crystal in the clock
"synch. status code: INVA / QUSE / QUEX / QUON”
" " (space) time by synchronisation
"synchronization status code: SYOF /
SYNC”
character no. 30 = "S"
daylight saving time
"U"
UTC
" " (space) standard time
character no. 31 = "!"
announcement of a DST or standard time changeover
"A"
announcement of a leap second
" " (space) no announcement
8.3.8.5.6.6.4 Example
(STX)D:18.07.02;T:4;U:12.34.56; _ _ _ _ (ETX)
( _ ) = Space
•
It is Thursday 18.07.02 - 12:34:56 o'clock
•
The clock is synchronous (synchronization status code: SYNC)
•
standard time (winter time)
•
no announcement of a changeover