6.3.2.2.6 Operation Mode
The network device usually adjusts the data stream and duplex mode to the device to which it
is connected (e.g. HUB, SWITCH) automatically. If the network device requires a certain speed
or duplex mode, this can be configured via the web interface. The value should only be
changed in special cases. The automatic setting is normally used.
In individual cases an enabled "Auto negotiate" might lead to problems be-
tween the network components and the adjustment process fails.
In such cases it is recommended to set the network speed of the Board
7052RC
and
the connected network components manually to the same
value.
6.3.2.2.7 Maximum Transmission Unit (MTU)
The Maximum Transmission Unit describes the maximum size of a data packet of a protocol
of the network layer (layer 3 of OSI model), measured in octets which can be transferred into
the frame of a net of the security layer (layer 2 of OSI model) without fragmentation.
Board 7052RC is going to be delivered with default setting 1356.