TPPL Configuration Code
MAN0984_Iss 4_01/19
Touchpoint Plus
Pt. No. 3011M5001
133
Technical Handbook
Chapter 14.
The following table shows how your TPPL configuration code (P/N) is displayed on the product label, which helps Technical Support to understand your system construction if
you need additional help.
Product
Name
Unit Type
Power
Mounting
Type
Input
Options
Relay
Options
Output
Options
Battery
External
Comm s
Web
Interface
Certificatio
n
TPPL
B = Base Unit
E = Expansion
Unit
A = AC
110/220 V
W = Wall
Mounted
A2 = 2ch mA
Input
S = 12 relays
4 = 4ch mA
Output
B = Backup
Battery
N = None
R = RTU
(Modbus)
N = None
R = Modbus,
TCP + Web
monitoring
T = Modbus
TCP/IP
W = Modbus
TCP + Web
configuration
N = None
V2 = 2ch mV
Input
A4 = 4ch mA
Input
D = 24 relays
8 = 8ch mA
Output
V4 = 4ch mV
Input
D = DC
18 32 V
A8 = 8ch mA
Input
N = None
V8 = 8ch mV
Input
N = No Relay
N = No mA
Output
D4 = Dual 4ch
mA/mV
Inputs
D8 = Dual 8ch
mA/mV
Inputs
P/N
Code:
(Example)
TPPL
B
A
W
A4
S
4
B
N
N
N
Table 16.
TPPL Configuration P/N Code Chart (example)