SV9520H SMARTVALVE™ SYSTEM CONTROL LINE VOLTAGE POLARITY SENSE MODELS
9
69-1383
.
Fig. 8. SV9520 typical wiring connection with 208907 Terminal Board.
Sequence of Operation
1.
Make sure the ignition system control switch is in
the ON position.
2.
Follow the sequence of operation as shown in
Fig. 11.
TROUBLESHOOTING
Troubleshooting with LED Indicator
Assistance (no cycling of appliance
power or thermostat call for heat since
appliance failure has occurred)
WARNING
Electrical Shock Hazard.
Can cause property damage, severe
injury or death.
Only a trained, experienced service technician
should perform this troubleshooting.
1. Check the system thermostat to make sure it
is in an active call for heat mode. (Do not cycle
the thermostat on and off at this time.)
2. Remove the appliance burner compartment
door. Do not interrupt the power to the SV9520
by opening any electrically interlocked panels.
3. Observe LED indicator on SV9520; check
and repair the system as noted in Table 9.
4. After LED flash code analysis and appliance
repair are complete, turn thermostat below
room temperature for 10 seconds; turn the
thermostat above room temperature to initiate
a new call for heat.
5. Observe the ignition sequence; comparing it
to the Sequence of Operation shown in Fig. 11.
Allow the new ignition sequence to proceed
until appliance lights or an abnormal or
unexpected event is observed. See next
section.
C1
C2
C3
40 VA
TRANSFORMER
L1
L1
L2
24 VAC
R
W
C
COM
XFMR
XFMR
LOAD
COMMON
M17607
AIR PROVING
SWITCH
NEUTRAL
NEUTRAL
HOT
ROLL-OUT
SWITCH
LIMIT
SWITCH
COMBUSTION
AIR BLOWER
AIR
DATA
1
L2
L1
(HOT)
TO 120 VAC, 60 HZ
POWER SUPPLY
THERMOSTAT
R
R
C
W
208907
TERMINAL BOARD
SV9520
HOT
SURFACE
IGNITER
FLAME ROD
POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
CONNECT THE 120V (HOT) LEAD TO L1 ON TERMINAL BOARD.
APPLIANCE CHASSIS MUST HAVE RELIABLE
CONNECTION TO EARTH GROUND.
1
2
3
2
3
AUXILIARY
LIMIT SWITCH
(OPTIONAL)
1
1
5
6
7
8
3
2
2
2
1
3
5
4
6
2
3
3
1
4
4
4
P1