view the system type
•
set the system path length
•
perform a system self test
•
check system alignment
•
initialise the system and make it live
Note: The 4-20 output is inhibited during this procedure. See the earlier description.
system type
The initial display after
Install
is chosen is in the following format:
System Type
tttttttt
where:
tttttttt
System type. The system type displayed is one of the following:
Display Text
System Type
Short Range
40m range system
Medium Range
120m range system
Long Range
200m range system
Duct Mount
0.5 - 5m range system
Note: It is not possible to change the system type. This is set during calibration and configuration
of the unit at the factory.
Path length
The following message is displayed:
Path Length
nnnn
where:
nnnn
The path length in metres.
The following ranges of path length can be entered for the system types:
System Type
Minimum Range (m)
Maximum Range (m)
Step Size (m)
Short Range
5
40
1
Medium Range
20
120
1
Long Range
120
200
1
Duct Mount
0.5
5
0.1
>
>
APPENDIX A - HANDHELD INTERROGATOR
Содержание Searchline Excel
Страница 1: ...Searchline Excel Infrared Gas Detectors Technical Handbook ...
Страница 72: ...72 MAN0530 Issue 10 11 09 Searchline Excel 2104M0506 7 CERTIFICATION 7 2 5 System Diagram ...
Страница 79: ...79 MAN0530 Issue 10 11 09 Searchline Excel 2104M0506 7 CERTIFICATION ...
Страница 80: ...80 MAN0530 Issue 10 11 09 Searchline Excel 2104M0506 7 CERTIFICATION With DX100 M Termination Unit ...