4. Configure the following schedule settings.
5. Click
Save
.
Reporting
Generating Event Reports
On the Alarms & Events window, you can download
Alarms/Events or Web events
.
1. Click
to open the menu, then click
Alarms & Events
or
Web Events
.
Interlocks
Enables you to disable the interlock, or programmed interaction
between two points. When enabled, this point ignores all interlock
actions to it, effectively disabling it from being a Reacting
Component.
TZ Card Toggle
Requires, like the First Card Rule, a valid card read within the
schedule to enable the schedule (period in which doors are
unlocked) to take effect. Unlike the First Card Rule, however, the
user can swipe the card a second time to return the doors to a
locked state.
Note
Both TZ Card Toggle and First Card Rule cannot be
enabled at the same time. Appears only on door lock
outputs.
First Card Rule
Requires a valid card read within the schedule to enable the
schedule (period in which doors are unlocked) to take effect.
Note
Both TZ Card Toggle and First Card Rule cannot be
enabled at the same time. Appears only on door lock
outputs.
Configuration
Description
Configuration
Description
Energized
Sets the period during which the output is automatically
energized.
Disable
Interlocks
Sets the period during which the interlock, a programmed
interaction between selected inputs, outputs, and groups will be
disabled. During the selected Schedule, this point ignores all
interlock actions to it, effectively disabling it from being a
Reacting Component during the Schedule. Outside of the
Schedule the point will react to interlocks as expected.
Содержание MPA1
Страница 1: ...Document 800 26311_Rev B July 2020 Access Control Unit MPA1 User Guide ...
Страница 2: ...Revisions Rev Date Revisions A 02 2020 Document created B 07 2020 Document updated with ULC Features ...
Страница 14: ... 13 Document 800 26311_ A April 2020 This page is intentionally left blank ...
Страница 72: ... 75 Document 800 26311_ A April 2020 This page is intentionally left blank ...
Страница 100: ...www honeywell com security 104 MPA1 User Guide This page is intentionally left blank ...
Страница 109: ... 113 Document 800 26311_ A February 2020 Click Open to load the file Confirm Yes when this warning comes up Success ...
Страница 119: ... 125 Document 800 26311_Rev B July 2020 ...