| 47
Document 800-26311_ A - April 2020
Note
The duress output feature requires the following configurations:
•
Duress must be enabled on the
Panel Configuration
>
Settings
>
Behaviour Settings
•
A schedule/schedule must be selected for
Card and PIN
in the Doors
configuration.
6. Enable or Disable
Reader B
.
The default setting is Disabled. A confirmation message
appears. Click
OK
to enable Reader B.
Use an Reader B if a door has readers on both sides (inside and outside).
7. Click
Save
.
Note
Should a conflict arise among the schedules set in the Access
Modes and Schedules section, priority is given in the following order:
•
Disable Reader
•
Lockdown Reader
•
Card and PIN
•
Card or PIN
•
PIN only
•
Card only
Therefore, the Disabled schedule has highest priority, and the Card
Only schedule has lowest priority.
Note
Readers must be enabled in two places, in
Panel Configuration
and here. Go
to
Panel Configuration
>
Settings
>
Behaviour Settings
Note
The access mode defined here for the door can be overridden by a card
assigned with a VIP card type. (See
for
information about assigning a VIP card type.)
Configuring Door Inputs
The Inputs tab allows you to configure the following settings:
•
Input Name
•
Input Modes
•
Shunt and Debounce
•
Scheduling
Содержание MPA1
Страница 1: ...Document 800 26311_Rev B July 2020 Access Control Unit MPA1 User Guide ...
Страница 2: ...Revisions Rev Date Revisions A 02 2020 Document created B 07 2020 Document updated with ULC Features ...
Страница 14: ... 13 Document 800 26311_ A April 2020 This page is intentionally left blank ...
Страница 72: ... 75 Document 800 26311_ A April 2020 This page is intentionally left blank ...
Страница 100: ...www honeywell com security 104 MPA1 User Guide This page is intentionally left blank ...
Страница 109: ... 113 Document 800 26311_ A February 2020 Click Open to load the file Confirm Yes when this warning comes up Success ...
Страница 119: ... 125 Document 800 26311_Rev B July 2020 ...