Document 800-26311_ A - February 2020
Space
Displays the name of the space where the alarm occurred.
Filter by Space
: You can filter alarms and events by the
space by clicking the filter icon
next to
Space
in the
header.
Severity
Indicates the importance of the event: Normal, Major, or
Critical.
Normal
: Indicates that the panel or device is back online,
valid card transactions, the input is back to the normal
state, or an output has been used.
Major
: Indicates an invalid card transaction, such as card
not found, invalid format, anti-passback violation, site
code violation, time-zone violation.
Critical
: Indicates that the panel or a device is offline, or
that an input is in an alarm state.
Filter by Severity
: You can filter alarms and events by the
severity by clicking the filter icon
next to Severity in the
header.
Type
Indicates the type of alarm/event, such as:
• Normal State
• Alarm State
• Ajar State
• Card Found
• Card Not Found
• Input Alarm
• Panel Offline
Filter by Type
: You can filter alarms and events by the type
by clicking the filter icon
next to
Type
in the header.
There are 61 event types from which to choose.
LN (Logical Device
Number)
A unique number starting at 1 that is assigned to an alarm
generating point. This number is never duplicated on a
Controller.
There is one exception to this: Door Readers.
PN (Physical Device
Number)
A number at the board level that is assigned to a specific
alarm generating point.
There is one exception to this: Door Readers.
Cred-PIN/Site
Identifies the card number, and either the PIN or site code
number of the card. Reports only events that have an
invalid Card Number, invalid Site Code, or invalid PIN.
Invalid Cards are reported by themselves. Invalid Site
Codes and invalid PINs are reported with the card number
that was presented along with them.
Filter by Cred-PIN/Site
: You can filter alarms and events
by the Cred-PIN/Site by clicking the filter icon
next to
Cred-PIN/Site
in the header, and then entering a card
holder number.
Table 3-1
Alarms & Events Fields
Field
Description
Содержание MPA1
Страница 1: ...Document 800 26311_Rev B July 2020 Access Control Unit MPA1 User Guide ...
Страница 2: ...Revisions Rev Date Revisions A 02 2020 Document created B 07 2020 Document updated with ULC Features ...
Страница 14: ... 13 Document 800 26311_ A April 2020 This page is intentionally left blank ...
Страница 72: ... 75 Document 800 26311_ A April 2020 This page is intentionally left blank ...
Страница 100: ...www honeywell com security 104 MPA1 User Guide This page is intentionally left blank ...
Страница 109: ... 113 Document 800 26311_ A February 2020 Click Open to load the file Confirm Yes when this warning comes up Success ...
Страница 119: ... 125 Document 800 26311_Rev B July 2020 ...