www.honeywell.com/security
20 |
MPA1 User Guide
Figure 2-2 Selecting Host/Loop Communication Tab
3. Set up Communication attributes (see
):
a. Select
Web
as Host Connection Type.
b.
Ethernet Virtual Loop
is the only available option.
c. Click
Save
.
Setting Up an Ethernet Port on page 6
5. Set up Network Configuration (see
):
a. Navigate to the
Network
field on the
Settings
tab.
b. Select
DHCP
or enter
Static IP
address assigned to Primary panel.
c. Click
Save
. The panel automatically reboots.
Note
It is recommended to set the Primary panel as a static IP address that is
different than the default address (192.168.1.150) such as 192.168.1.100.
The Primary panel must be set to the same subnet as the Secondary panels
in order for the EVL to work properly (i.e., if DHCP server is assigning
Secondary panels to 129.17.27.XXX, then Primary needs to also be set to
129.17.27.XXX).
Содержание MPA1
Страница 1: ...Document 800 26311_Rev B July 2020 Access Control Unit MPA1 User Guide ...
Страница 2: ...Revisions Rev Date Revisions A 02 2020 Document created B 07 2020 Document updated with ULC Features ...
Страница 14: ... 13 Document 800 26311_ A April 2020 This page is intentionally left blank ...
Страница 72: ... 75 Document 800 26311_ A April 2020 This page is intentionally left blank ...
Страница 100: ...www honeywell com security 104 MPA1 User Guide This page is intentionally left blank ...
Страница 109: ... 113 Document 800 26311_ A February 2020 Click Open to load the file Confirm Yes when this warning comes up Success ...
Страница 119: ... 125 Document 800 26311_Rev B July 2020 ...