B9.
For installation of the swageless terminal cable end part an acid free
gasket material e.g. Silkaflex 221 should be used. It has to be put in
the body of the cable end part.
Therefore the swageless end terminal has to be screwed on and the
gasket material has to be put in the clamp jaw body and also in the
gaps of the clamp jaws. After that the swageless end terminal has to
be screwed together. This act has to be retried till the gasket
material discharge out of the opening where the rope has to be
inserted. Then the swageless end terminal has to be cleaned. The
clamp jaws must not use again.