page 15 of 24
D2.
The characteristic load affecting the extension post must not exceed
22 kN under any circumstances.
D3.
At working in falling off dangerous areas it has to pay attention to the
safe standing of the user. Tripping points in the entrance and working
area have to be avoided.
D4.
Functional capability of the system has to be inspected visually
before and while using .the installed fall protection system.
D5.
Warning!
The anchor device must not used anymore if the anchor eye was
charged by a fall. In this case the anchor device has to be checked
by a competent person and if necessary changed.
D6.
The anchor device Söll Vi-Go extension post may only be used in
combination with the following safety equipment:
- at working with falling hazard fall arrest system in accordance to
EN 363 and energy absorber EN 355
- rescue systems in accordance to EN 1496, 1479 and 1498
D7.
The system of the personal protective equipment against falling (only
with energy absorber) or rescue system has to be chosen that a
collision of the user with the ground or collision with other bars can be
avoided. For that the information for use of the manufacturer has to
be checked.
D8.
In order to secure against fall from a height the karabiner hook (pos.
1) of the lanyard has to be installed on the eye of the anchor steel
plate (pos. 2) and locked to avoid unintended disconnecting.
Fig. D2
D9.
Danger!
The karabiner hook of the lanyard must not disconnect from the
anchor device before the user is protect by another solution against a
fall.