Lyric Controller Installation and Reference Guide
- 22 -
System Operation
System Operation
System Operation
System Operation
Key/Touchscreen
Key/Touchscreen
Key/Touchscreen
Key/Touchscreen Operation
Operation
Operation
Operation
The touchscreen icons allows the user to arm and disarm the system, and perform other system functions, such
as bypassing zones. Zone and system conditions (alarm, trouble, bypass) are displayed on the LCD. When an
alarm occurs, the console and external sounder (if installed) will sound, and the zone(s) in alarm will be
displayed. Pressing any key will silence the keypad sounder for 10 seconds (only once). Disarming the system
will silence both console and external sounders. When the system is disarmed, any zones that were in an alarm
condition during the armed period will be displayed (memory of alarm). To clear this display, simply repeat the
disarm sequence by selecting the Disarm button and entering the Security Code. The console also features
chime annunciation, and three panic key icons for silent, audible, fire or personal emergency alarms. These keys
can notify the Central Station of an alarm condition, if that service is connected.
Pani
Pani
Pani
Panic Key
c Key
c Key
c Key/Icons
/Icons
/Icons
/Icons
There are four panic icons that are displayed (if programmed) when the “Panic” key is selected for
approximately four seconds. The panic key screen will timeout if a selection is not made within ten seconds.
The keys can be used to manually initiate alarms and send a report to the Central Station. Each can be
individually programmed for 24-hour silent, audible, personal or fire emergency responses. The panic function is
activated when the respective keys is pressed. The panic functions are identified by the system as follows:
Zone
Zone
Zone
Zone
Function
Function
Function
Function
995
Fire Emergency
996
Medical Emergency
998
Local Alarm
999
Police Emergency
Important:
Important:
Important:
Important: For the silent panic functions to be of practical value, the system must be connected to a Central
Station.
Security Codes
Security Codes
Security Codes
Security Codes
Installer Code
Installer Code
Installer Code
Installer Code
The installer programs the 4-digit Installer Code initially as part of the programming procedure. The
factory default Installer Code is 4
4
4
4----1111----1111----2
2
2
2, but may be changed in the Installer Code programming field.
The Installer Code is the only code that allows entry into Installer Programming mode.
Master Code
Master Code
Master Code
Master Code
In normal operation mode, the Master (Security) Code is used to enter the 4-digit User Security Codes and enter
the Master User Tools Menu mode.
E
E
E
Enter/
nter/
nter/
nter/Change
Change
Change
Change the Master
the Master
the Master
the Master Code
Code
Code
Code b
b
b
by I
y I
y I
y Installer
nstaller
nstaller
nstaller.
.
.
.
The factory default Master Code for the Lyric Controller is set to 1-2-3-4. The Master Code is used to enter the
4-digit User Security Codes.
SCREEN
SCREEN
SCREEN
SCREEN
ACTION
ACTION
ACTION
ACTION
Ready To Arm - Chime
lyric-018-V2
Voice Command
Advanced
WiFi Config
Back
Keypad
Date Time
Users
Reminders
Events
1.
After entering the User Tools/Programming Menu, select the
“Users” icon on the User Menu screen. The system displays the
User Code Programming screen.
2. Select “Master”, then select “Edit”.
3. Enter a new 4-digit Master (Security) Code on the displayed
keypad. The system displays the new code on the left side of the
screen.
4. Select “Done” when you are finished.
5. The system returns to the Master Code Programming screen.
Secondary User Codes
Secondary User Codes
Secondary User Codes
Secondary User Codes
In normal operation mode, the Master (Security) Code can be used to assign up to 46 secondary 4-digit security
codes, including a Guest Code and a Duress Code. The Master Code can also be used to individually remove
secondary codes from the system. Refer to the Lyric Controller User Manual for additional information.