Lyric Controller Installation and Reference Guide
- 11 -
Installing
Installing
Installing
Installing the Control (Continued)
the Control (Continued)
the Control (Continued)
the Control (Continued)
!
The
The
The
The LYRIC
LYRIC
LYRIC
LYRIC----CDMA
CDMA
CDMA
CDMA Communications Module is only available in the continental United States,
Communications Module is only available in the continental United States,
Communications Module is only available in the continental United States,
Communications Module is only available in the continental United States,
Alaska
Alaska
Alaska
Alaska and Hawaii
and Hawaii
and Hawaii
and Hawaii....
Communication Modules
Communication Modules
Communication Modules
Communication Modules
The Lyric Controller supports Central Station reporting using wireless/cellular and Wi-Fi communications
devices. They also support upload/download programming capability via the Internet. This allows site
maintenance independent of Central Station monitoring, and modification to sites globally via the Internet. Refer
to the Programming Guide (p/n 800-18077) for information regarding programming and registration.
Additionally, an internal Z-Wave module allows the Lyric Controller to support Home Automation functions.
(refer to the Lyric User Guide (p/n 800-16078 for additional information.) The controllers are compatible with
the following AlarmNet Communication Modules:
Model
Model
Model
Model
Description
Description
Description
Description
LYRIC-3G
GSM Cellular Communications Module
LYRIC-3GC (Canada)
GSM Cellular Communications Module
LYRIC-CDMA
CDMA Cellular Communications Module
LYRIC-LTE (Series)
LTE Cellular Communications Module
Communic
Communic
Communic
Communications Module
ations Module
ations Module
ations Module 24
24
24
24----Hour Standby Power
Hour Standby Power
Hour Standby Power
Hour Standby Power
If 24-hour standby is required, the Super High Capacity battery (p/n 300-03866-AIO) must be installed.
!
RF E
RF E
RF E
RF Exposure
xposure
xposure
xposure
WARNING: The
WARNING: The
WARNING: The
WARNING: The Lyric
Lyric
Lyric
Lyric Controller
Controller
Controller
Controller must be installed to provide a separation distance of at least 7.8
must be installed to provide a separation distance of at least 7.8
must be installed to provide a separation distance of at least 7.8
must be installed to provide a separation distance of at least 7.8
in (20 cm) from all persons and not co
in (20 cm) from all persons and not co
in (20 cm) from all persons and not co
in (20 cm) from all persons and not co----located or operated in conjunction with any other
located or operated in conjunction with any other
located or operated in conjunction with any other
located or operated in conjunction with any other
transmitter except in accordance with FCC multi
transmitter except in accordance with FCC multi
transmitter except in accordance with FCC multi
transmitter except in accordance with FCC multi----transmitter pr
transmitter pr
transmitter pr
transmitter product procedures.
oduct procedures.
oduct procedures.
oduct procedures.
Insta
Insta
Insta
Install
ll
ll
ll and Confi
and Confi
and Confi
and Configur
gur
gur
gure
e
e
e C
C
C
Communication
ommunication
ommunication
ommunication Module
Module
Module
Module
Follow the steps and refer to the figure below to install the Communications Module.
Installing the
Installing the
Installing the
Installing the Cellular
Cellular
Cellular
Cellular Communications Module
Communications Module
Communications Module
Communications Module
1.
At the Installer Programming Tools Menu screen select “Test” OR at the Master User Tools Menu
Programming screen select “Advanced”.
2. Select “Install Cellular Module” and follow the prompts displayed on the controller or follow the steps below.
3. Remove controller side cover (bezel).
4. Remove the screw securing the module to the controller (if installed).
5. Remove the existing Cellular Communications Module (if installed).
6. Install the Cellular Communications Module into the controller.
7. Ensure that the Communications Module is properly seated into the controller.
8. Insert the side cover (bezel) into the controller.
9. Slide the side cover (bezel) down to lock it in place and secure the Communications Module.
10. Select OK to complete the installation.
N
N
N
NOTE
OTE
OTE
OTE:::: The Communication Path will be dynamically adjusted when a Cellular Communication Module is
installed or removed.
11. Enable the Communications Module, configure alarm reporting and module supervision and register the
device. Refer to the “Program Communicator” and “Communications Diagnostics” sections in the
Programming Guide (p/n 800-18077). OR Log on to the AlarmNet 360 website (http://alarmnet360.com).
The
The
The
The Communications Module
Communications Module
Communications Module
Communications Module must be registered
must be registered
must be registered
must be registered with
with
with
with AlarmNet 360
AlarmNet 360
AlarmNet 360
AlarmNet 360 before downloading o
before downloading o
before downloading o
before downloading or
r
r
r
alarm reporting can take place.
alarm reporting can take place.
alarm reporting can take place.
alarm reporting can take place.