Lyric Gateway Installation and Reference Guide
- 38 -
SIA Quick Reference Guide
SIA Quick Reference Guide
SIA Quick Reference Guide
SIA Quick Reference Guide
Programming Section
Programming Section
Programming Section
Programming Section
Feature
Feature
Feature
Feature
Range
Range
Range
Range
Shipping Default
Shipping Default
Shipping Default
Shipping Default
SIA Requirement
SIA Requirement
SIA Requirement
SIA Requirement
Installation and
Installation and
Installation and
Installation and Setup Guide or Programming Guide
Setup Guide or Programming Guide
Setup Guide or Programming Guide
Setup Guide or Programming Guide
Reporter
Reporter
Reporter
Reporter
Exit Error
Not selectable
Enabled
Enabled
Recent Closing
Not selectable
Enabled
Enabled
Alarm Cancel
Enabled or Disabled
Enabled
Enabled
System
System
System
System
Number of
Reports (Swinger
shutdown)
1 to 6 Reports
2 Reports
2 Reports
Alarm Report
Delay (Abort
Window)
No Delay, 15, 30 and 45
seconds
30 seconds
30 seconds*
Area
Area
Area
Area
Entry Delay # 1
None, 15, 30, 45, 60
and 90 seconds and 2,
3 or 4 minutes
30 seconds
30 seconds minimum
Entry Delay # 2
None, 15, 30, 45, 60
and 90 seconds and 2,
3 or 4 minutes
30 seconds
30 seconds minimum
Exit Delay
45, 60, 90 and 120
seconds
60 Seconds
45 seconds minimum
Restart Exit Time
Enabled or Disabled
Yes (Enabled)
Enabled
Exit Warning
Not selectable
Yes (Enabled)
Enabled
Auto Stay
Arming
Enabled or Disabled
Yes (Enabled)
Enabled
Cross Zone Delay
30 seconds and 2
minutes (in 30 second
increments), 3 minutes
and 4 minutes
None (Disabled)
Enabled and two zones
programmed
Zones
Zones
Zones
Zones
Fire Alarms
Zone Type “Fire with
Verification” must be
selected for Fire Zone
95
Disabled
Disabled
User Guide
User Guide
User Guide
User Guide
User Functions/
User Functions/
User Functions/
User Functions/
User Access
Duress
Duress Code is
Programmed by Master
User as User 48
Disabled
Disabled
System Functions/
System Functions/
System Functions/
System Functions/
Testing the System**
System Test
System tests provided
as a User Function
n/a
n/a
Communications
While the system is in
Test mode, no alarm
reports are sent to the
Central Station
Disabled
Disabled
* Combined Entry Delay and Alarm Report Delay (Abort Window) should not exceed 1 minute.
** Refer to the User Guide for procedures on Testing the System.
Содержание Lyric LCP300-LC
Страница 42: ...Lyric Gateway Installation and Reference Guide 42 Notes Notes Notes Notes ...
Страница 43: ...Lyric Gateway Installation and Reference Guide 43 Notes Notes Notes Notes ...
Страница 44: ...Lyric Gateway Installation and Reference Guide 44 Notes Notes Notes Notes ...
Страница 45: ...Lyric Gateway Installation and Reference Guide 45 Notes Notes Notes Notes ...