LCBS CONNECT SOLUTION
31-00118EFS—01
2
Multispeed Fan ............................................................................................................................................................ 20
Multispeed Fan Theory and Operation...................................................................................................................................20
Two speed motor .............................................................................................................................................................................20
VFD application................................................................................................................................................................................20
Direct drive "ECM" motor..............................................................................................................................................................20
Theory and Operation Accessory Loops ............................................................................................................... 23
How do Accessory Loops work?.................................................................................................................................................23
Service Alerting Theory and Fundamentals ........................................................................................................ 24
How does service alerting work?...............................................................................................................................................25
Terminal Load, Zone Demand Alert. ........................................................................................................................................25
Space Humidity Alert.....................................................................................................................................................................25
Space Zone Carbon Dioxide Level Alert .................................................................................................................................26
Differential Pressure Alerting, Filter Loading ......................................................................................................................26
Alerting Details.................................................................................................................................................................................27
Appendix, Wiring Diagrams ...................................................................................................................................... 30
1. Master Points List - Configurable and Fixed Function Points.................................................................................30
2. Master Application Inventory - All Wiring Diagrams....................................................................................................30
3. Configurable Input and Output Assignments Wiring Diagram ...............................................................................31
4. Fixed Input and Output Assignments Wiring Diagram ...............................................................................................32
5. Two Heat Two Cool Integrated Economizer Single Temperature Changeover Limit ......................................33
6. Two Heat Two Cool Integrated Economizer Differential Enthalpy Changeover and
Temperature Limit .....................................................................................................................................................................34
7. Two Heat Two Cool Integrated Economizer Differential Enthalpy Changeover and Temperature
Limit and Demand Controlled Ventilation.......................................................................................................................35
8. Three Heat Three Cool Multispeed Fan with Variable Frequency Drive ...............................................................36
9. Single Stage Heat Pump with Economizer Differential Enthalpy Changeover and
Temperature Limit .....................................................................................................................................................................37
10. Two Stage Heat Pump with Economizer Differential Enthalpy Changeover and Temperature Limit ...38
11. Simple Dehumidification......................................................................................................................................................39
12. Two Speed Fan with Discrete Fan Outputs Two Heat and Two Cool ...................................................................40
13. Outdoor Ambient Lighting Control with Photosensor Input to Control Outdoor Light Level ..................41
14. Sylk Sensor Installation Relating to LCBS Connect Controller.............................................................................42
INTRODUCTION
The LCBS Connect Solution features controllers that support multiple CVAHU applications, including rooftop units, split
systems and air to air heat pumps and a new Gateway that permits controller data to be sent from individual CHAHU
controllers via the internet to the new LCBS Connect Cloud. The new Honeywell Cloud capability gives our control system
users unprecedented access to data remotely via standard smart phones, tablets, and personal computers. Honeywell
also performs data analysis, called “analytics,” that will permit service contractors and building owners to effectively and
efficiently manage HVAC assets. Here are a few specific features of the new LCBS Connect solution.
—
Occupancy Control.
Daily and holiday schedules are available to ensure that building occupants, employees, and
visitors are comfortable when they are in the building and that owners achieve maximum energy savings when no
one is occupying the building. Honeywell patented Adaptive Intelligent Recovery monitors outdoor and indoor cli-
mate conditions to ensure comfortable conditions when building occupants arrive.
—
Advanced Sensing.
Supports multiple space temperature sensors (Up to five) for effective temperature value
(Average, Minimum, Maximum, and Smart) and options for return air sensing. Supports space and return air tem-
perature, humidity, and CO2 sensing.
—
Heating and Cooling Control.
Provides three stages of heating and cooling for conventional equipment and up to
three compressor stages for air to air heat pumps. LCBS Connect heat pump controllers support up to two (2)
stages of auxiliary heat.
—
Economizer Control.
Supports nine different economizer strategies that address all climatological zones in North
America.
—
Dehumidification Control.
Three (3) dehumidification strategies for dehumidification control are supported.
First, if the equipment is capable, a reheat mode can be programmed to provide precise dehumidification opera-
tion. Second, dehumidification equipment can be controlled through a direct LCBS Connect output to provide
dehumidification. Third, extended minimum cooling runtime can be selected supporting the dehumidification
process.