Configuration
Document 800-03650
Rev D
89
02/09
Setting Alarm-Out Actions
1.
Highlight the desired field under the Alarm-Out heading, and press
. A list of
Alarm Outputs and the toggle for the Beep appears.
2.
Select the Alarm Output connectors that you would like to activate whenever the
DVR detects motion on the selected camera.
You can also set the DVR internal buzzer to sound if motion is detected on the
selected camera.
Note
For the Alarm-Out action, the alarm output and beep you select
should be set to the Event mode in the Alarm-Out setup screen
(Schedule tab).
Setting Motion Detection Notifications
1.
Highlight the desired field under the Notify heading, and press
. The Motion
Detection Notify menu appears.
2.
You can toggle the entire list On and Off by highlighting Notification and
pressing .
You can toggle the individual items On and Off by highlighting them and pressing
.
3.
Highlight OK and press
to accept your changes.
Note
For the Notify action, the notify item you select should be
enabled in the Notification setup screen and the DVR should be
registered in the RASplus.
Actions 2 Tab Settings
In the Text-In Actions 2 tab, you can choose PTZ camera preset positions and spot
monitor actions.
Highlight the Actions 2 tab. The Motion Detection Actions 2 screen displays.
Содержание HRSD16
Страница 12: ...Tables 12 ...
Страница 18: ...18 ...
Страница 22: ...Introduction 22 ...
Страница 138: ...Operation 138 ...
Страница 140: ...USB Hard Disk Drive Preparation 140 ...
Страница 158: ...Time Overlap 158 ...
Страница 160: ...Troubleshooting 160 ...
Страница 162: ...Connector Pinouts 162 ...
Страница 163: ...Map of Screens Document 800 03650 Rev D 163 02 09 H Map of Screens ...
Страница 164: ...Map of Screens 164 ...
Страница 166: ...System Log Notices 166 ...
Страница 175: ......