3.3 WIRING – UNSHIELDED TWISTED PAIR (UTP) OPTION, CONTINUED
IF YOU ARE USING A 3M OR 10M EXTENSION CABLE, USE THE
WIRING DIAGRAM SUPPLIED WITH THE EXTENSION CABLE.
THERMOSTAT:
ON 70
0
°F
OFF 9 °F
OUTPUT 96W
TABLE 1
HD6 POWER REQUIREMENTS: 24VAC
±10%
TABLE 2
HEATER/BLOWER POWER REQUIREMENTS: 24VAC @ 4A
DOME WIRING, 13.5 (340) LG., SEE BELOW
FEMALE BNC FOR VIDEO
INTERFACE BOARD
THREADED NIPPLE
1.62”
(41.1mm)
9.54”
(242.3mm)
12.29” REF
(312.2mm)
INTERFACE BOARD 518753-1030
W2
W4
SW1
W1
24VAC DOME POWER
24VAC DOME POWER
DATA RX
DATA RX
DATA TX
DATA TX
-
+
-
+
GROUND
24VAC L1
NOT USED
24VAC L2
ALARM 1 OPTION
ALARM 2 OPTION
NOT USED
NOT USED
ALARM 1 OPTION COMMON
ALARM 2 OPTION COMMON
NOT USED
NOT USED
BLACK
WHITE
BLACK/WHITE
BLACK/ORANGE
WHITE/BLACK
WHITE/VIOLET
BROWN
RED
ORANGE
YELLOW
GREEN
BLUE
VIOLET
GRAY
WHITE/BROWN
WHITE/RED
TO 24VAC
HEATER/B LOWER
ASSEMBLY
WHITE/ORANGE
WHITE/YELLOW
VIDEO
(CAT5)
VIDEO (CAT5)
+
-
DATA OPTION
WIRING REQUIRES
SPECIAL FIRMWARE
HD6 WEATHER DOME WIRING
UTP OPTION (VIDEO ON UNSHIELDED TWISTED PAIR)
CAUTION: VERIFY THE TYPE OF CONNECTOR (14-PIN OR NONE) PRIOR TO
CONNECTING WIRING OR EQUIPMENT DAMAGE MAY OCCUR.
0-90
90-180
180-270
270-365
365-455
0-300
300-600
600-900
900-1200
1200-1500
Off
Off
On
Off
Off
Off
Off
Off
On
Off
Off
On
Off
Off
On
Off
On
Off
Off
Off
DIP Switch
Control & Video Over UTP
SW1
UTP Cable
Switch Position
Feet
Meters
1
2
3
4
* Use lowest switch setting possible.
Ex: If cable run is 900 feet, use 600-900 switch setting.
Make sure only one switch is set to ON.
Note: If an active receiver (e.g., NVT Model NV-652R)
is used at the monitor, set all switches to OFF.
If the compensation is not enough, set SW1-1 to ON.
Ensure all other switches are set to OFF.
Jumper W1
Jumper W2
Jumpers W3 & W4
Terminated
Position 1 & 2 Last Dome on Data Loop
Unterminated
Position 2 & 3 All Intermediate Domes on Data Lo op
Positions 2 & 3 All Domes
UTP
Positions 1 & 2
Not Used
Positions 2 & 3
To use the board as standard (video over coax & 2-wire RS485):
Positions 1 & 2
Positions 2 & 3
Jumper W3
Jumper W4
AWG
22
20
18
16
14
12
MAX. DISTANCE TO DOME
65 FEET (19 METERS)
100 FEET (30 METERS)
160 FEET (48 METERS)
260 FEET (79 METERS)
420 FEET (128 METERS)
650 FEET (198 METERS)
24 VAC POWER @1.1A
AWG
MAX. DISTANCE TO DOME
24VAC HEATER POWER
MAXIMUM WIRE LENGTHS
18
16
14
12
62 FEET (18.9 METERS)
99 FEET (30.2 METERS)
158 FEET (48.2 METERS)
251 FEET (76.5 METERS)
Figure 18: Unshielded Twisted Pair (UTP) Option – HD6 Weather Dome – No
Connector
Rev. 1.02
40
900.0696
1-Aug-06
Содержание HD6 Series
Страница 1: ...HD6 Series Housings Installation Manual 900 0696 August 2006 Rev 1 02 ...
Страница 4: ...Rev 1 02 iv 900 0696 1 Aug 06 ...
Страница 8: ...Rev 1 02 viii 900 0696 1 Aug 06 Notes ...
Страница 12: ...Rev 1 02 2 900 0696 1 Aug 06 Notes ...
Страница 28: ...Rev 1 02 18 900 0696 1 Aug 06 Notes ...
Страница 51: ...Rev 1 02 41 900 0696 1 Aug 06 Notes ...
Страница 52: ...Rev 1 02 42 900 0696 1 Aug 06 Notes ...
Страница 53: ...Rev 1 02 43 900 0696 1 Aug 06 Notes ...
Страница 54: ...Rev 1 02 44 900 0696 1 Aug 06 Notes ...
Страница 55: ...Rev 1 02 45 900 0696 1 Aug 06 Notes ...