2.1 DROPPED CEILING HOUSING, CONTINUED
6. Place the housing in the ceiling mount.
The space between the wing tabs on the housing and
the housing flange should be greater than the
thickness of the ceiling tile and the mount. Make sure
the wing tabs on the housing are staggered so the tabs
are not at the same height.
7. Position the wing tabs flat against the housing . Push the housing through the hole
in the ceiling tile and the mount (some jostling is required). Using a screwdriver,
turn the three screws in the housing clockwise to rotate the tabs out and tighten the
tabs against the ceiling mount.
8. Attach the safety cable (from the building support structure) to the housing by
threading the cable through a looping sleeve, through the hole in the tab (beside the
conduit fitting) on the housing , and then through the looping sleeve again. Secure
by crimping the looping sleeve. The safety cable tab on the housing can be rotated
as needed for clearance in the ceiling.
9. Place the ceiling tile with the plate and the housing on the ceiling support grid.
10. Refer to
Section 3
for wiring instructions.
Refer to
Section 3.2
for standard wiring.
Refer to
Section 3.3
for Unshielded Twisted Pair (UTP) wiring.
Rev. 1.02
4
900.0696
1-Aug-06
Содержание HD6 Series
Страница 1: ...HD6 Series Housings Installation Manual 900 0696 August 2006 Rev 1 02 ...
Страница 4: ...Rev 1 02 iv 900 0696 1 Aug 06 ...
Страница 8: ...Rev 1 02 viii 900 0696 1 Aug 06 Notes ...
Страница 12: ...Rev 1 02 2 900 0696 1 Aug 06 Notes ...
Страница 28: ...Rev 1 02 18 900 0696 1 Aug 06 Notes ...
Страница 51: ...Rev 1 02 41 900 0696 1 Aug 06 Notes ...
Страница 52: ...Rev 1 02 42 900 0696 1 Aug 06 Notes ...
Страница 53: ...Rev 1 02 43 900 0696 1 Aug 06 Notes ...
Страница 54: ...Rev 1 02 44 900 0696 1 Aug 06 Notes ...
Страница 55: ...Rev 1 02 45 900 0696 1 Aug 06 Notes ...