– 8 –
Table 1 – 7720P Normal and Shift Key (shift LED lit) Functions
KEY
NORMAL KEY FUNCTION
SHIFT KEY FUNCTION
BS/ESC
[BS]: Press to delete entry
[ESC]: Press to quit program mode; also can reset
programming defaults*
↓
/
↑
[
↓
]: Scroll down programming
[
↑
]: Scroll up programming
N/Y
[N]: Press for "NO" answer
[Y]: Press SHIFT-Y for "YES" answer
SHIFT
Press before pressing a SHIFT key function. Will light SHIFT LED. LED goes out once a key is pressed.
Press again for each SHIFT function desired.
1/A
[1]: For entering the number 1
[A]: For entering letter A
2/B
[2]: For entering the number 2
[B]: For entering letter B
3/C
[3]: For entering the number 3
[C]: For entering letter C
4/D
[4]: For entering the number 4
[D]: For entering letter D
5/E
[5]: For entering the number 5
[E]: For entering letter E
6/F
[6]: For entering the number 6
[F]: For entering letter F
7/S
[7]: For entering the number 7
[S]: For entering letter S
8/T
[8]: For entering the number 8
[T]: For entering letter T
9/X
[9]: For entering the number 9
[X]: For entering letter X
SPACE
[SPACE]: For scrolling option list
No SHIFT function
0
[0]: For entering the number 0
No SHIFT function
#/ENTER
[#/ENTER]: Starts programming
mode; Press to accept entries
No SHIFT function
*Active only when the "Exit Programming Mode" prompt is displayed.
Programming Conventions
Programming is accomplished by answering a series of prompts (questions). Most prompts require only
a [Y]es or [N]o response, while others require a numerical response (ID numbers, etc.).
The current value is displayed on the second line in parentheses ( ). A "?" indicates an invalid entry.
Use the [ENTER] key to accept the current entry and proceed to the next prompt. If the entered value
is invalid, pressing [ENTER] re-displays the prompt; the next prompt is not displayed until a valid
answer is entered.
Use the up/down arrow keys to scroll through the programming questions without changing any values.
Press the [ESC] key to go to the end of the list of questions.
PROGRAMMING
ECP Mode Programming
The GSMVLP4G supports ECP messaging to communicate with the control panel. Lynx Plus
Series/ReadyGuard Plus Series control send Contact ID format alarms to the GSMVLP4G directly on
the 4-wire console bus. Refer to Table 2 for GSMVLP4G programming and follow the prompts.
Press the [ENTER] key to begin programming.
NOTE:
The central station can remotely block access to local device
programming. If this has been done, the following prompt appears:
Access to Prog
Mode Denied