– 10 –
PROMPTS
ENTRY
OPTIONS
DESCRIPTION
8
Exit Prog. Mode?
(Y/N)_
[Y], [N]
[ESC]
Exits program mode.
Press [N] to go back to Prompt 3.
Press [ESC] to load factory defaults.
Refer to the Exiting Programming Mode
paragraph in this section.
9
Device Mode
(ECP)_
•
ECP
•
4204 Emu
•
Two 4204s
Press the [space] key to scroll through the
modes of operation. Press [ENTER] to select
ECP
mode.
IMPORTANT NOTE:
Do not select any other mode.
Setting up the Multi-Mode Feature
Multi-Mode enables users to receive e-mail notification of system events. Since the communication
device is emulating a 4204 or two 4204 modules, there is no additional hardware to install.
E-mail notification is intended as a convenience for the user, and does not replace
Central Station reporting of critical events (alarms, troubles, etc.).
Enabling the Multi-Mode Feature
•
Multi-Mode must be enabled during account programming on the AlarmNet Direct website by
selecting "Enabled" at the Multi-Mode prompt.
Configuring Multi-Mode
The communication device emulates one or two standard 4204 relay modules for purposes of triggering
events for sending e-mail reports. If "4204 Sourced" is selected, you must enable Multi-Mode Address 6
or 7 in Lynx Plus/ReadyGuard Plus Series Programming Field *86. If "2-4204 Sourced" is selected, you
must enable both. When "4204 Sourced" is selected, the user can be notified of up to four events, and
when "2-4204 Sourced" is selected, the user can be notified of up to eight system events. The Multi-
Mode Address must match the address of the e-mail trigger module enabled in the Lynx
Plus/ReadyGuard Plus Series control panel in Field *86.
Events used to send e-mail messages are defined on the Honeywell Total Connect website, and must
correspond to (e-mail) event triggers programmed in the control panel as events 09-16 in field *80
Device Programming Menu Mode.
PROMPTS
ENTRY
OPTIONS
DESCRIPTION
10
Multi Mode
(Disabled)_
•
Disabled
•
4204
Sourced
•
2-4204
Sourced
•
Enhanced
Reports
Enable if you want system events sent by e-
mail to the user. Select "4204 Sourced" to send
up to four events, or "2-4204 Sourced" to send
up to eight events; “Enhanced Reports” to send
full status of the panel for Total Connect 2.x
support. Disable for normal alarm processing
and go to Prompt 13 "Primary City ID"
prompt. Press the [space] key to scroll through
choices
.
11
Multi Mode Addr
(12)
[01-30]
NOTE:
This prompt will only appear if the Multi-Mode
feature has been enabled.
This address must be programmed if using the
Multi- Mode (e-mail notification) feature. The
device address must be unique from the
normal Device Address and the Keypad
Address used for Remote Access. If the Multi-
Mode setting is “Enhanced Reports”, the