– 16 – 

 

 

Registration BAD 
Pri ID – Need PIN

  

Displayed if this is a repair/replacement, or an error was made in programming 

the Primary account information of GSMVLP4G for an existing account.  This 

prompt appears for 2 seconds.  See the Replacing an existing module section 

below for further displays. 

Replacing an existing module using the programming tool 

 

Enter PIN# 

 

 

This prompt appears after pressing the 

down arrow [

]

 on the 7720P. Enter a 

4-digit alphanumeric PIN number provided by your central station, your dealer 

or an authorized AlarmNet representative.  

NOTE:

   If you are replacing an existing "C Series" radio, you can enter the last four-digits of 

the "C Series" MIN number. 

Press the [ENTER] key. 

 

Registering … 
 

The registration message is sent and the unit waits for acknowledgement. 

 

Registration 
SUCCESS 

If the PIN is valid, the new GSMVLP4G is registered and the old unit 

unregistered. Additionally, AlarmNet sends a substitution alarm to the central 

station. 

 

Registration BAD 
 

If you entered an invalid PIN, the appropriate message is displayed depending 

on which account number is being replaced (see above for exact wording). The 

registration process is repeated. 

NOTE:

   Each attempt causes a substitution alarm to be sent to the central station. 

Register by Phone 

You can register the module by calling the AlarmNet Technical Assistance Center (TAC) at 1-800-222-

6525 (Option 1). 

You will need the following information:  

 

MAC number (found on the label). 

 

Subscriber information (provided by the central station), including a city code, CSID, and 

subscriber ID. 

 

When instructed to do so, enter the Installer Code and OFF on the Lynx Plus control to initiate the 

registration. 

Содержание GSMVLP4G

Страница 1: ...GSMVLP4G GSMVLPCN4G GSM Module with 2 Way Voice Installation and Programming Guide 800 12200V2 5 15 Rev A ...

Страница 2: ...cess Feature 11 Enabling Remote Access 11 Selecting the User Interface 11 ECP Status Codes 12 Exiting Programming Mode 12 Setting the Factory Defaults 13 REGISTRATION 13 Registering the GSMVLP4G 13 Register through the AlarmNet Direct Website 14 Register Using the Test Message Registration Switch 14 Register Using the Programming Tool 14 Replacing an existing module using the programming tool 15 R...

Страница 3: ... detection Network communication failure In the event the AlarmNet network does not hear a supervisory message from the module within a specified time Supervision option 24 hours 30 days or none AlarmNet notifies the central station of a communication failure Communication path failure In the event the module detects a communication path failure the control panel can be notified of a trouble condi...

Страница 4: ...the control s back case as shown on Figure 2 Figure 2 FCC IC Label location RF Exposure WARNING The antenna s used for this transmitter must be installed to provide a separation distance of at least 7 8 in 20 cm from all persons and must not be co located or operating in conjunction with any other transmitter except in accordance with FCC multi transmitter product procedures Mise en Garde Expositi...

Страница 5: ... the back case as shown on Figure 3 6 Connect the provided ECP power cable between the GSMVLP4G module and the PC board and route the cable as shown in Figure 4 This cable provides DC power and ground for the module and ECP connections For best radio performance the wires ECP power cable battery and shielded audio cables must be routed as shown in Figure 4 7 Make the wiring connections and install...

Страница 6: ...ith controls using firmware rev 20 xx The short cable is intended for use with controls using firmware rev 30 xx or higher GSMVLP4G Cable Routing for controls with rev 20 xx firmware use long cable GSMVLP4G Cable routing for modified LYNX Plus PCB design for controls with rev 30 xx firmware use short cable ...

Страница 7: ...rimary City ID two digit number 2 Primary Central Station ID two digit hexadecimal number 3 Primary Subscriber ID four digit number 4 MAC ID and MAC CRC number located on the outside of box and on the GSMVLP4G 5 After programming is complete you must transfer the data to the GSMVLP4G and the module must be registered Refer to the Registration section for further instructions Using a 7720P Programm...

Страница 8: ...rogramming mode Press to accept entries No SHIFT function Active only when the Exit Programming Mode prompt is displayed Programming Conventions Programming is accomplished by answering a series of prompts questions Most prompts require only a Y es or N o response while others require a numerical response ID numbers etc The current value is displayed on the second line in parentheses A indicates a...

Страница 9: ...assword has been assigned this prompt appears after pressing N at the Program Device prompt If a password is desired press Y and go to Prompt 6 Enter Password 5 Change Password Y N _ Y N If a password has already been assigned this prompt appears after pressing N at the Program Device prompt Press Y if you want to change the password NOTE To clear an existing password without entering a new one an...

Страница 10: ...d 86 If 2 4204 Sourced is selected you must enable both When 4204 Sourced is selected the user can be notified of up to four events and when 2 4204 Sourced is selected the user can be notified of up to eight system events The Multi Mode Address must match the address of the e mail trigger module enabled in the Lynx Plus ReadyGuard Plus Series control panel in Field 86 Events used to send e mail me...

Страница 11: ...dyGuard Plus Series Controls do not support second account reporting 12 Primary City ID _ 01 99 Enter the 2 digit primary city ID 01 99 decimal 13 Primary CS ID 01 FE Enter the 2 digit primary central station ID number 01 FE HEX 14 Primary Sub ID 0001 9999 Enter the 4 digit subscriber account number 0001 9999 decimal 15 Device Address 03 _ 01 30 The GSMVLP4G communicates with the panel as a Long R...

Страница 12: ... using the Remote Access feature Enter the appropriate device address NOTE This address must be set to 1 18 Supervision 24 Hours _ 30 Day 24 Hour None The AlarmNet network must hear at least one supervisory message from the module during this supervision period otherwise AlarmNet notifies the central station that a communication failure has occurred If the supervision period is changed after regis...

Страница 13: ...on with control panel GSMVLP4G lost contact with AlarmNet GSMVLP4G is not registered account not activated GSMVLP4G shutdown Exiting Programming Mode To exit the programming mode press N in response to the REVIEW question Then press Y to the Exit Prog Mode question Upon exiting the message Checking Root File TX Path will be displayed and the configuration file at the server is updated to log the c...

Страница 14: ...ed GSMVLP4G is indicated on the Status Display as Status lit Message slow blinking and Fault not lit Figure 6 Unregistered GSMVLP4G Status Display In Normal Operation Throughout this document the following key is used to describe LED state Figure 7 LED Key Upon completion of the registration process a GSMVLP4G transmits a registration message and receives a registration validation indicating that ...

Страница 15: ...ile registration is in progress Once the registration has been completed successfully the GSMVLP4G GSMVLPCN4G enters normal operating mode the Status green LED goes out and the Message yellow LED is lit to indicate that the power on reset message is waiting to be sent This message will appear at the receiving station as E339 803 The description may read Trouble Exp Mod Reset If registration is not...

Страница 16: ...ge is sent and the unit waits for acknowledgement Registration SUCCESS If the PIN is valid the new GSMVLP4G is registered and the old unit unregistered Additionally AlarmNet sends a substitution alarm to the central station Registration BAD If you entered an invalid PIN the appropriate message is displayed depending on which account number is being replaced see above for exact wording The registra...

Страница 17: ...ce key to go to the next field Press the backspace key to go to the previous field SCID xxxxx xxxxx xxxxx xxxxx SCID Display Displays the identification number assigned to the SIM card SCID in this device Press the space key to go to the next field Press the backspace key to go to the previous field IMEI xxxxxxxx xxxxxx x IMEI Display Displays the identification number assigned to the GSMVLP4G mod...

Страница 18: ...ss Technology Either 2G OR 3G 4G EC NO Carrier Noise Ratio CNR Press the space key to get to the next screen Press the backspace key to go to the previous field CNtry NetW LAC xxx xxx xxxxx GSMVLP4G Status Display Screen 3 4G Radio operating with 3G 4G Service CNtry Country Code NetW Network Code LAC Local area code Press the space key to get to the next screen Press the backspace key to go to the...

Страница 19: ...yed Note If a 2G radio is installed this display will not appear Press the space key to get to the next screen Press the backspace key to go to the previous field CNtry NetW LAC xxx xxx xxxxx GSMVLP4G Status Display Screen 3 4G Radio operating with 2G Service OR 2G Radio CNtry Country Code NetW Network Code LAC Local area code Press the space key to get to the next screen Press the backspace key t...

Страница 20: ...armNet DN arrow Enter PIN Registration with PIN for Replacement Module Registers a replacement GSMVLP4G with AlarmNet once programmed using the existing PIN 0 Force Server Update Y N Force Upload of Configuration File to Server Pressing Y will force the device to upload its entire configuration file to the server Pressing N cancels the operation NOTE If the GSMVLP4G module is not initialized when ...

Страница 21: ...e module and the receiving tower Refer to Figure 9 Table 3 Status and Signal Strength LED Operation LED COLOR LED DESCRIPTION GREEN STATUS ON GSMVLP4G is NOT registered with AlarmNet OFF GSMVLP4G is registered with AlarmNet FAST BLINK Download session with Compass in progress SLOW BLINK In unison with yellow LED Registration in progress YELLOW MESSAGE ON Message transmission pending QUICK PERIODIC...

Страница 22: ...arm Code ECP Mode Restore Code Power On Reset E339 C0803 ECP Supervision E355 C0000 R355 C0000 Communication Path Restore R350 C0951 Test 5555 5555 9 Note The control panel sends its own general code E353 for a trouble condition GSMVLP4G DOWNLOADING General Information The GSMVLP4G can be used to provide high speed up downloading to Lynx Plus ReadyGuard Plus Series control panels over the GPRS net...

Страница 23: ...sions 5 625 x 2 25 Electrical Input Voltage 12VDC powered by the Lynx Plus ReadyGuard Plus Series Control Range 5 5 VDC 12 VDC Quiescent Current 40mA Peak Current During Transmit 650mA Environmental Operating temperature 20ºC to 55ºC for ULC installations 0ºC to 49ºC Storage temperature 40º to 70ºC Humidity 0 to 95 relative humidity non condensing Altitude to 10 000 ft operating to 40 000 ft stora...

Страница 24: ...ician for help This Class B digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la classe B est conforme à la norme NMB 003 du Canada FCC IC Statement This device complies with Part 15 of FCC Rules and RSS 210 of Industry Canada Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interferenc...

Отзывы: