24
75 Series Mobile Computer User Guide
Configure the Heater Feature
You can configure the following parameters in
Enterprise Settings
or the computer
registry to optimize the operation of the heaters to fit your specific application
environment.
Heater Setting
Description
Temperature monitoring
Registry Key: TempMonitoring
Enable or Disable the heater feature and temperature
monitoring.
In freezer heater activation
Registry Key: PreemptiveHeating
Enable or Disable the automatic pre-heat feature.
When enabled, modify the following parameters:
• Pre-heat enable delay timer
• Pre-heat power level
Heater enabled temperature
Registry Key: EnableT
Set the temperature (°C) that the computer must fall to
before the heaters turn on. The
Heater enabled
temperature
is used to identify cold storage entry.
Once this temperature is detected, the
Heater enabled
delay
timer starts.
Heater enabled delay (minutes)
Registry Key: ChillTime
Set the time limit (minutes) for how long the computer
must remain at or below the defined
Heater enable
temperature
before:
• the heaters turn on if in Automatic mode, or
• the
Pre-heat enabled delay
timer starts when
In freezer activation
(Preemptive mode) is
enabled.
Note: If you remove the computer from cold storage
before the timer expires, the system does not turn
on the heaters, saving battery power.
Exit freezer temperature change trigger
Registry Key: DeltaT
Set the sensitivity of the cold storage exit trigger.
To detect a cold storage exit, the computer looks for a
quick rise in temperature (°C), defined by the
Exit
freezer temperature change trigger
value, over a brief
period of time.
Exit freezer heater on duration
Registry Key: DurationHeater
Set the length of time (minutes) the heaters stay on at
full power (100%) once the computer detects a quick
rise in temperature, defined by the
Exit freezer
temperature change trigger
value (°C).
Note: The heaters may turn off before the timer has
expired if a temperature reading indicates the
computer is warm enough or you manually turn
off the heaters by tapping the heater icon once.
Pre-heat enabled delay (minutes)
Registry Key: PreemptiveDelay
Set the length of time (minutes) that the computer
waits after the
Heater enabled delay
timer has expired
before activating the low power pre-heat window
feature.
Pre-heat power level (%)
Registry Key: DutyCycle
Set the power level (%) of the heaters used during the
pre-heat cycle.
Содержание CN75
Страница 2: ......
Страница 4: ......
Страница 12: ...viii 75 Series Mobile Computer User Guide ...
Страница 56: ...44 75 Series Mobile Computer User Guide ...
Страница 62: ...50 75 Series Mobile Computer User Guide 3 Tap OK ...
Страница 82: ...70 75 Series Mobile Computer User Guide ...
Страница 86: ...74 75 Series Mobile Computer User Guide ...
Страница 108: ...96 75 Series Mobile Computer User Guide ...
Страница 116: ...104 75 Series Mobile Computer User Guide ...
Страница 140: ...128 75 Series Mobile Computer User Guide ...
Страница 254: ...242 75 Series Mobile Computer User Guide ...
Страница 255: ......
Страница 256: ... Honeywell 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com Cx75 W65 EN UG Rev A 08 17 ...