75 Series Mobile Computer User Guide
23
How Preemptive Mode Works
Preemptive mode minimizes screen defrosting time but slightly reduces cold
storage battery life since the heaters enter a low power pre-heat stage before the
computer detects a rise in the ambient temperature.
The heater only enters the low power pre-heat stage once the following conditions
are met in the order listed:
1. The computer detects the ambient temperature has lowered below the set
Heater enable temperature
.
2. The
Heater enabled delay timer
expires. A snowflake
icon appears in the
status bar.
3. The
Pre-heat enabled delay
timer expires.
Note:
Once the computer enters the pre-heat stage, the icon changes from a
snowflake
to a heater
.
Pre-heating keeps the windows warm to minimize condensation and frost when
the computer is removed from cold storage allowing for quicker defrost times. The
heaters switch to full power to defrost the windows when the computer detects a
quick rise in the ambient temperature.
In Preemptive mode, the cold storage battery life ranges from a maximum of
6 hours to a minimum of 1.5 hours depending on the
Pre-heat enabled delay
time
set. The window defrost times range from zero to a maximum of one minute with
factory default settings.
You can configure the heater operation for your individual environment in
Enterprise Settings or by editing the computer registry values. To learn more, see
How to Manually Turn the Heaters On/Off
If you want to manually turn the heaters on or off while in cold storage, tap the
snowflake
or heater icon
in the status bar.
If the
In freezer heater activation
setting is enabled (Preemptive mode), the
Pre-heat enabled delay
timer is not stopped if the icons are used to turn the heater
on or off. The timer continues to run and the heaters still turn on when the timer
expires.
If the
In freezer heater activation
setting is disabled, the
Pre-heat enabled delay
timer is not used and pre-heating does not automatically start, but the snowflake
icon
can still be tapped to turn on the heaters for pre-heating.
Содержание CN75
Страница 2: ......
Страница 4: ......
Страница 12: ...viii 75 Series Mobile Computer User Guide ...
Страница 56: ...44 75 Series Mobile Computer User Guide ...
Страница 62: ...50 75 Series Mobile Computer User Guide 3 Tap OK ...
Страница 82: ...70 75 Series Mobile Computer User Guide ...
Страница 86: ...74 75 Series Mobile Computer User Guide ...
Страница 108: ...96 75 Series Mobile Computer User Guide ...
Страница 116: ...104 75 Series Mobile Computer User Guide ...
Страница 140: ...128 75 Series Mobile Computer User Guide ...
Страница 254: ...242 75 Series Mobile Computer User Guide ...
Страница 255: ......
Страница 256: ... Honeywell 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com Cx75 W65 EN UG Rev A 08 17 ...