Page 1019
1 Dec 2003
34-45-4
7
MAINTENANCE MANUAL
CAS-100 COLLISION AVOIDANCE SYSTEM
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
The three possible results of the test are:
(a) No faults (unit and system ok)
(b) System or input faults (unit ok, system failed)
(c) Internal faults (unit failed/system failed)
To push the Select button with the caret at SYSTEM FAILED or UNIT FAILED causes a
display screen with the entries that include the applicable found faults. When faults are
found, START TEST is selectable and a retest is possible. The selection of GO BACK
causes the previous screen with a selectable item to be shown. That previous screen is
the same as it was when previously visited. A GO BACK is possible when the user
pushes a Select button with an in operation selectable item. To go back to the previous
screen, hold the Scroll button and push the Select button.