Item
Description
1
Rear shell
2
Moisture filter
3
Pump quick connector
4
Pump inlet
5
Machine screw (1)
6
Particulate filter
1.
Remove the one machine screw from the pump inlet and gently lift the bottom of the
inlet outward at a 45° angle.
2.
Gently lift the pump inlet upwards to remove. Ensure the hook on the pump inlet
clears the housing.
The particulate filter is located inside the pump inlet and the moisture filter is located
on the rear shell.
3.
Depending upon the circumstance, replace either just the particulate filter or both.
Refer to Particulate Filters and Moisture Filters in this section.
4.
Reattach the pump inlet and replace the screw. Tighten the screw using 3-4 in-lbs.
torque. Do not overtighten.