Section 3: Programming the 7847i/7847i-E
3-17
PROMPTS
ZONE
TRIG.
4204/
2-4204
ENTRY OPTIONS
DESCRIPTION
35
Open/Close Zone
(0)_
✔
✔
Zone Trig:
[3-7]
4204: [1-4]
2-4204: [1-8]
[0] = not used
Enter the zone number to be used for open/close
(arm/disarm) reports.
This zone assignment must be unique from the
Telco Zone selected in Prompt 34.
Zone Trigger Mode:
If any zone is programmed
for "report only if armed," zone 7 cannot be used
as an open/close zone. If Lynx Panic is enabled,
zone 3 cannot be used.
4204 Mode:
If any zone is programmed for "report
only if armed," zone 4 cannot be used as an
open/close zone.
2-4204 Mode:
If any zone is programmed for
"report only if armed," or if tamper is enabled,
zone 8 cannot be used as an open/close zone.
NOTE:
Connect an open/close (arm/disarm)
trigger (or relay output) from the control panel to
the open/close zone.
36
Zn1 Trigger Type
(V+)_
✔
•
(EOLR)
•
(V+)
•
(V–)
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
37
Invert Zn1 Y/N
(N)_
✔
[Y], [N]
Inverts the alarm and normal states of the zone 1
trigger; otherwise uses normal input signal.
38
Restore Zn1 Y/N
(Y)_
✔
✔
[Y], [N]
Enables restore reporting for zone 1.
39
Delay Zn1 (secs)
(00)_
✔
✔
[01-15]
[00]=no delay
Defines the reporting delay in seconds for zone 1.
40
Rpt Zn1 ONLY if
Armed (N)_
✔
✔
[Y], [N]
Report alarms on zone 1 ONLY if the conditional
zone (zone 7 in zone trigger mode; zone 4 in 4204
mode; or zone 8 in 2-4204 mode) is triggered
(armed).
If [N], always reports alarms on zone 1.
41
Invert Zn2 Y/N
(N)_
[Y], [N]
Inverts the alarm and normal states of the zone 2
trigger; otherwise uses normal input signal.
42
Restore Zn2 Y/N
(Y)_
✔
[Y], [N]
Enables restore reporting for zone 2.
43
Delay Zn2 (secs)
(00)_
✔
✔
[01-15]
[00]=no delay
Defines the reporting delay in seconds for zone 2.
44
Rpt Zn2 ONLY if
Armed (N)_
✔
✔
[Y], [N]
Reports alarms on zone 2 ONLY if the conditional
zone (zone 7 in zone trigger mode; zone 4 in 4204
mode; zone 8 in 2-4204 mode) is triggered
(armed).
If [N], always reports alarms on zone 2.
If Lynx Panic is enabled, then skip to Prompt 49: "Rpt Zn3 ONLY if Armed."
45
Zn3 Trigger Type
(V+)_
✔
•
(EOLR)
•
(V+)
•
(V–)
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
46
Invert Zn3 Y/N
(N)_
✔
[Y], [N]
Inverts the alarm and normal states of the zone 3
trigger; otherwise uses normal input signal.
Содержание AlarmNet 7847i-E
Страница 2: ......
Страница 14: ...7847i 7847i E Installation and Setup Guide 2 6 ...
Страница 42: ...7847i 7847i E Installation and Setup Guide 5 4 ...
Страница 52: ...7847i 7847i E Installation and Setup Guide B 2 ...
Страница 56: ...7847i 7847i E Installation and Setup Guide D 2 ...
Страница 57: ...NOTES ...
Страница 58: ...7847i 7847i E Installation and Setup Guide NOTES ...
Страница 59: ...NOTES ...
Страница 60: ...7847i 7847i E Installation and Setup Guide NOTES ...
Страница 61: ...NOTES ...
Страница 62: ...7847i 7847i E Installation and Setup Guide NOTES ...