7847i/7847i-E Installation and Setup Guide
3-2
Each key of the 7720P has two possible functions: a normal function and a Shift function.
To perform a normal key function, simply press the desired key. To perform a Shift function,
press the [shift] key, and then press the appropriate key.
The prompts in this document reflect use of the 7720P Programming Tool. Table 2 below lists
each normal and shift key function.
Table 2. 7720P Normal and Shift Key (shift LED lit) Functions
KEY
NORMAL KEY FUNCTION
SHIFT KEY FUNCTION
BS/ESC
[BS]: Press to delete entry
[ESC]: Press to quit program mode; also can reset
programming defaults*
↓
/
↑
[
↓
]: Scroll down programming
[
↑
]: Scroll up programming
N/Y
[N]: Press for "NO" answer
[Y]: Press SHIFT-Y for "YES" answer
SHIFT
Press before pressing a SHIFT key function. Will light SHIFT LED. LED goes out once a key
is pressed. Press again for each SHIFT function desired.
1/A
[1]: For entering the number 1
[A]: For entering letter A
2/B
[2]: For entering the number 2
[B]: For entering letter B
3/C
[3]: For entering the number 3
[C]: For entering letter C
4/D
[4]: For entering the number 4
[D]: For entering letter D
5/E
[5]: For entering the number 5
[E]: For entering letter E
6/F
[6]: For entering the number 6
[F]: For entering letter F
7/S
[7]: For entering the number 7
[S]: For entering letter S
8/T
[8]: For entering the number 8
[T]: For entering letter T
9/X
[9]: For entering the number 9
[X]: For entering letter X
SPACE
[SPACE]: For scrolling option list
No SHIFT function
0
[0]: For entering the number 0
No SHIFT function
#/ENTER
[#/ENTER]: Press to accept entries
No SHIFT function
* Active only when the "Exit Programming Mode" prompt is displayed.
Using the Control Panel Programming Mode
Some control panels support programming of the 7847i/7847i-E through the control
panel programming mode (e.g., Vista-128BP). If programming through the control
panel, only the ECP Mode programming options are available. The "mode" questions
will not be displayed, and the mode cannot be changed. For a description of key
functions on the control panel keypad, and how they map to the 7720P Programming
tool, refer to the control panel's Programming Guide.
Programming Conventions
Programming is accomplished by answering a series of prompts (questions). Most prompts
require only a [Y]es or [N]o response, while others require a numerical response (ID
numbers, etc.).
The current value is displayed on the second line in parentheses ( ). A "?" indicates an
invalid entry.
Use the [ENTER] key to accept the current entry and proceed to the next prompt. If the
current value is invalid, pressing [ENTER] re-displays the prompt; the next prompt is not
displayed until a valid answer is entered.
Use the up/down arrow keys to scroll through the programming questions without changing
any values. Press the [ESC] key to go to the end of the list of questions.
ECP Mode Programming
Press the [ENTER] key to begin programming.
NOTE:
The central station can remotely block access to local
device programming. If this has been done, the
following prompt appears:
Access to Prog
Mode Denied
Содержание AlarmNet 7847i-E
Страница 2: ......
Страница 14: ...7847i 7847i E Installation and Setup Guide 2 6 ...
Страница 42: ...7847i 7847i E Installation and Setup Guide 5 4 ...
Страница 52: ...7847i 7847i E Installation and Setup Guide B 2 ...
Страница 56: ...7847i 7847i E Installation and Setup Guide D 2 ...
Страница 57: ...NOTES ...
Страница 58: ...7847i 7847i E Installation and Setup Guide NOTES ...
Страница 59: ...NOTES ...
Страница 60: ...7847i 7847i E Installation and Setup Guide NOTES ...
Страница 61: ...NOTES ...
Страница 62: ...7847i 7847i E Installation and Setup Guide NOTES ...