7847i/7847i-E Installation and Setup Guide
3-14
PROMPTS
ZONE
TRIG.
4204/
2-4204
ENTRY OPTIONS
DESCRIPTION
26
Keypad Address
(28)_
✔
[01-30]
Must be programmed if using either the Remote
Access feature or Direct Wire downloading.
Enter
the appropriate device address.
NOTES:
1. This address must also be programmed as an
alpha keypad in the control panel. If a full
enhanced graphic interface to the system is
desired, the keypad must also be enabled as an
AUI (Advanced User Interface) device. DO NOT
connect to an actual keypad (or any other
device) assigned to this address.
2. If using a compatible LynxR-I series control
(when available), this address must be set to
“1.”
3. This address must be unique from the "Device
Address" entered in Prompt 23, and cannot
equal that device address plus 1 (one) if using
2-4204 mode.
27
Supervision
(24 Hours)_
✔
✔
•
24 Hours
•
1 Hour
•
US UL Line
6 Min
•
CN UL Line
Lvl 3 (3 Min)
•
US UL Line
90 Sec
•
CN UL Line
Lvl 4 (90 Sec)
•
CN UL Line
Lvl 5 (75 Sec)
•
None
•
30 Day
The AlarmNet network or the 7810iR-ent if
Private LAN is enabled on the 7847i-E, must hear
at least one supervisory message from the module
during this supervision period; otherwise,
AlarmNet or the 7810iR-ent if Private LAN is
enabled on the 7847i-E, notifies the central
station that a communication failure has
occurred. If the supervision period is changed
after registration, you must re-register the
module.
Press the [space] key to scroll through choices.
✔
✔
Sets how long an undeliverable alarm is retried
for delivery to the central station. If the message
is not validated, it is retried until the old alarm
time is reached or the message is validated.
Press the [space] key to scroll through choices.
28
Old Alarm Time
10 Minutes_
•
10 Min.
•
15 Min.
•
30 Min.
•
1 Hr
•
2 Hrs
•
4 Hrs
•
8 Hrs
•
12 Hrs
•
24 Hrs
UL NOTE:
Must be 10 minutes.
Содержание AlarmNet 7847i-E
Страница 2: ......
Страница 14: ...7847i 7847i E Installation and Setup Guide 2 6 ...
Страница 42: ...7847i 7847i E Installation and Setup Guide 5 4 ...
Страница 52: ...7847i 7847i E Installation and Setup Guide B 2 ...
Страница 56: ...7847i 7847i E Installation and Setup Guide D 2 ...
Страница 57: ...NOTES ...
Страница 58: ...7847i 7847i E Installation and Setup Guide NOTES ...
Страница 59: ...NOTES ...
Страница 60: ...7847i 7847i E Installation and Setup Guide NOTES ...
Страница 61: ...NOTES ...
Страница 62: ...7847i 7847i E Installation and Setup Guide NOTES ...