Zn ZT P RC HW: RT
01 09 1 10 EL 1
Zn
ZT P RC IN: L
10 00 1 10 :RF
–
Summary Screen
01-64 = zone number; [
∗
] to continue; 00 = quit
OR [D] to go to prompts for wireless key programming templates
A summary screen appears, showing zone 1’s currently programmed values.
Enter the zone number being programmed, then press [
∗
], which displays a summary
screen for that zone. See next prompt (zone 10 in this example).
If programming a wireless key,
press the [D] key then skip to the Wireless Key
Programming Templates section following this section. When [D] is pressed, you can choose
from a series of preset templates for easy programming of wireless key zones.
When all zones have been programmed, press
00
at this prompt to quit this menu mode.
Zn
ZT P RC IN: L
10 00 1 10 RF
1
Zone Programming
ZT = see Zone Type chart shown in *56 Menu Mode
“
Zone Type
”
prompt
P = partition 1, 2, 3 (common); RC = 1 (send CID report); 0 (no report)
IN = input type; L = loop number
[
∗
] to continue
A summary screen with the selected zone’s current programming appears.
Begin programming zone information as follows:
•
Enter Zone Type (ZT), Partition (P), Report Code (RC; 0-9 only; use *56 mode to enter
hex codes), and Input Device Type (IN)* sequentially, but not the Loop No. (L).
•
Use the [A] (Advance) and [B] (Back) keys on the keypad to move the cursor within the
screen.
•
Use the [C] key to copy the previous zone’s attributes.
Press [
✱
] to save the programming and continue to the serial number/loop number prompt.
If needed, you can press the [#] key to back up without saving.
* If HW (hardwired) or AW (Auxiliary) is entered for Input Device Type, the next screen
will be similar to the prompt shown, except that HW or AW will be displayed under “IN”.
If RF, BR, or UR is entered, a prompt for Serial and Loop number will be displayed, as
follows.
10 INPUT S/N: L
A X X X - X X X
–
Serial number
S/N = serial number; L = loop number; [
∗
] to continue
Manually enter the serial number (found on the transmitter label), by typing digits in the
“X” locations, using the [A] (advance) or [B] (back) keys as required. You can also perform
two open and close sequences; for button-type transmitters that means pressing and
releasing the button twice.
NOTE
:
If you want to copy the previous zone’s serial number, press the [C] key.
Press [
✱
] to advance to the loop number, then enter loop number.
Press [
✱
] to accept the existing serial and loop number and continue to the “Confirm”
prompt below. If necessary, press [#] to back up and re-enter or edit the serial number.
10 INPUT S/N:
L
A 0 0 0 - 0 0 0 0 0
To Delete a Serial Number
[
∗
] to continue
To delete an existing serial number, enter
0
in the loop number field. The serial number
will change to all 0's as shown.
If
0
was entered in error, simply re-enter the loop number, and the serial number will
return to the display.
10 XMIT TO CONFIRM
PRESS
✱
TO SKIP
Confirm
[
∗
] to continue
The prompt to confirm appears
.
This prompt will only appear if the first prompt after
entering
✱
58 was answered “Yes.” To confirm, activate the loop input or button that
corresponds to this zone.
The system checks for duplicate. If a duplicate exists, a long error beep will sound.
Press [#] to back up and re-enter the serial and/or loop number.
Menu Mode Programming
5-5
Содержание Ademco VISTA-21iPSIA
Страница 26: ...Installation and Setup Guide 2 20 ...
Страница 78: ...Installation and Setup Guide 6 8 ...
Страница 84: ...Installation and Setup Guide 8 4 ...
Страница 88: ...Installation and Setup Guide 9 4 ...
Страница 89: ...Notes 9 5 ...
Страница 90: ...Notes Installation and Setup Guide 9 6 ...