*43
Primary/Secondary Account Numbers
*44
Enter 4 or 10 digits, depending on selection in
*45
*48 Report Format field. Enter 0
–
9; # + 11 = B,
*46
# + 12 = C, # + 13 = D, # + 14 = E, # + 15 = F.
*43:
Partition 1 primary. To clear entries:
∗
43
∗
.
*44:
Partition 1 secondary. To clear entries:
∗
44
∗
.
*45:
Part. 2 prim. To clear entries:
∗
45
∗
.
*46:
Part. 2 second. To clear entries:
∗
46
∗
.
*47
Phone System Select
If Central Station Receiver
is
not
on WATS line:
0 = Pulse Dial; 1 = Tone Dial
If Central Station Receiver
is
on WATS line:
2 = Pulse Dial; 3 = Tone Dial
Select the type of telephone service.
*48
Report Format (Primary/Secondary)
0 = 3+1, 4+1 ADEMCO L/S STANDARD
1 = 3+1, 4+1 RADIONICS STANDARD
2 = 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD
5 = ADEMCO 10-digit Contact ID
®
6 = 4+2 ADEMCO EXPRESS
7 = ADEMCO 4-digit Contact ID
®
8 = 3+1, 4+1 ADEMCO L/S EXP.
9 = 3+1, 4+1 RADIONICS EXP.
Select format for primary/secondary phone numbers.
*49
Split/Dual Reporting
0 = standard/backup reporting only (see Backup Reporting
below)
To Primary No.
To Secondary No.
1 = alarms, restore, cancel
others
2 = all except open/close, test
open/close, test
3 = alarms, restore, cancel
all
4 = all except open/close, test
all
5 = all
all
Backup Reporting:
All reports are sent only to the
primary number unless unsuccessful after 8 attempts.
If unsuccessful, the system will make up to 8 attempts
to send all reports to the secondary number. If still
unsuccessful after the 16 attempts, the system displays
the “COMM. FAILURE” message (FC for fixed-word
displays).
*50
Burglary Dialer Delay
0 = no dial delay; 1 = 15 secs; 2 = 30 secs; 3 = 45 secs
UL: must be
0.
SIA Guidelines: delay must be minimum 15 seconds
V21iPSIA:
Delay Time:
1 = 15 secs; 2 = 30 secs; 3 = 45 secs
Delay Disable:
0 = use delay set in entry 1
1 = dial delay disabled for zones listed in zone list 6
(use zone list 6 to enter those zones that require
dial delay to be disabled; these zones ignore the
setting in entry 1)
UL: Dial delay plus entry delay must not exceed one
minute; use zone list 6 to disable dial delay from
appropriate zones, if necessary.
Provides delay of “BURGLARY ALARM” report to the
central station, which allows time for the subscriber to
avoid a false alarm transmission. This delay does not
apply to zone type 24 alarms (silent burglary) or to 24-
hour zone types 6, 7, and 8 (silent panic, audible alarm,
auxiliary alarm), which are always sent as soon as they
occur.
*53
SESCOA/Radionics Select
0 = Radionics (0-9, B-F); 1 = SESCOA (0-9 only)
Select SESCOA or Radionics format.
Select
0
for all other formats.
*54
Dynamic Signaling Delay
0 = disabled (both signals sent);
1
–
15 = entry times a 15-second delay.
e.g., 1 = 15 seconds, 2 = 30 seconds, etc.
Intended for use with IP/GSM reporting.
This field lets you select the time the panel should wait
for acknowledgment from the first reporting destination
(primary dialer or IP/GSM; see
∗
55) before it attempts
to send a message to the second destination. Delays can
be selected from 0 to 225 seconds, in 15-second
increments. This delay is per message. If
0
is entered in
this field, the control panel will send redundant reports
to both Primary Dialer and IP/GSM.
NOTE:
If
∗
55 is set to “0,” use minimum of 30 seconds
to avoid redundant IP report. However, this value may
need to be adjusted (ex. 45 secs) depending on the
reporting environment.
UL Installations:
For UL Burglar Alarm installations with Line Security,
Dynamic Signaling Delay must be
0
. Reports will be
sent to both the dialer and the IP/GSM.
*55
Dynamic Signaling Priority / AAV Enable
0 = Primary Dialer first / using AAV via phone line
1 = IP/GSM module first for alarm reports / not using AAV
This field selects the primary communication path
(dialer or communication device) for reporting of
primary phone number events
†
(see
∗
49 Split/Dual
Reporting) and if used, enables AAV (AAV sessions use
the phone line only).
Use
∗
29 IP/GSM menu mode to enable the
communication device being used.
†
Reports intended for the secondary phone number are
not sent via the communication device.
For Dynamic Signaling Priority:
Select the initial
reporting destination for messages as follows:
Primary Dialer First selected (
0
):
•
If acknowledged before delay expires (see
∗
54), then
message will not be sent via LRR.
•
If not acknowledged before delay expires, message is
sent to both the Primary Phone No. and via LRR.
Communication Device First (LRR) selected (
1
):
•
If acknowledged before delay expires, then message
will not be sent to the primary dialer.
•
If not acknowledged before delay expires, message is
sent to both the Primary Phone No. and via LRR.
For AAV Path Select:
•
If using the AVS system, option 0 (primary dialer
first) must always be used; AAV sessions can occur
only over the phone line with this control.
*56
Zone Programming Menu Mode
For programming zone information.
See Zone Programming section for procedures.
*57
Function Key Menu Mode
For programming keypad function keys.
See Function Key section for procedures.
Data Field Programming
4-3
Содержание Ademco VISTA-21iPSIA