5800 Series Transmitter Input Loop Identification
All of the transmitters illustrated below have one or more unique factory assigned input (loop) ID codes. Each of
the input loops requires its own programming zone
(e.g., a 5804's four inputs require four programming zones).
5802MN
ENROLL AS
"UR" OR "RF"
LOOP
1
V20P-006-V0
5817
ENROLL AS "RF"
5890
ENROLL AS
"RF" OR "RM"
LOOP 1
5808
ENROLL AS "RF"
LOOP 1
5809
ENROLL AS "RF"
5850 (GBD)
ENROLL AS "RF"
(Green)
(Red)
(Yellow)
5 8 0 4 B D
ENROLL AS "BR"
LOOP 4
YOU MUST
ENROLL
THIS BUTTON
SET
HOUSE
CODE
LOOP 3
LOOP 1
LOOP 2
5804
ENROLL AS "BR"
ON
5816MN
ENROLL AS "RF"
LOOP 2
(REED)
5816
ENROLL AS "RF"
LOOP 1
(TERMINALS)
LOOP 2
(REED)
LOOP 3
(TERMINALS)
5819S (WHS & BRS)
ENROLL AS "RF"
LOOP 1
(INTERNAL
SHOCK
SENSOR
LOOP 2
(REED)
5 8 1 9
ENROLL AS "RF"
LOOP 2
(REED)
LOOP 3
(TERMINALS)
LOOP 1
(TERMINALS)
5 8 0 1
ENROLL AS
"UR" OR "RF"
LOOP 3
LOOP 1
LOOP 2
LOOP 4
YOU MUST
ENROLL
THIS
BUTTON
LOOP 1
LOOP 2
LOOP 4
YOU MUST
ENROLL
THIS
BUTTON
LOOP 3
LOOP
1
MOTION
LOOP 2
(AUX.
CENTER)
LOOP 1
(PRIMARY)
LOOP 3
(AUX.
RIGHT)
LOOP 1
(TERMINALS)
ALTERNATE
POSITION
FOR LOOP 2
OFF
NOTE
: For information on any transmitter not
shown, refer to the instructions accompanying
that transmitter for details regarding loop
numbers, etc.
UL NOTE:
The following transmitters are
not intended for use in UL
installations:
5802MN, 5802MN2, 5804,
5804BD, 5814, 5816TEMP,
5819, 5819WHS & BRS, and
5850.
Compatible 5800 Series Transmitters Table
Model Product
Input
Type
Description
5801 Wireless
Panic
Transmitter
UR or RF
•
Four pushbuttons, each with a unique input (loop) code.
•
Programmable responses (e.g., Panic, Arm, Disarm, etc.)
5802 Pendant
(Personal
Emergency Transmitter)
BR Only
•
Has single pushbutton.
•
Usually programmed for response type of 24-Hr audible or 24-Hr
Silent (other zone responses are possible).
5802CP
Belt Clip (Personal
Emergency)
BR Only
Same as 5802.
5802MN Miniature
(Personal
Emergency Trans.)
UR or RF
Same as 5802.
5804 Wireless
Key
Transmitter
BR Only
•
Has four pushbuttons, each with a unique input (loop) code.
•
Programmable responses (e.g., Arm, Disarm, etc.)
5804BD Bi-Directional
Wireless Key
BR
•
House ID must be set.
•
Requires 5800TM Transmitter Module.
•
Can indicate system status via its 2 LEDs and built-in sounder.
•
Has four pushbuttons, each with a unique input (loop) code.
•
Operates the system similarly to wired keypads.
5806
5807
5808
Wireless
Photoelectric Smoke
Detectors
RF
One-piece smoke detectors with a built-in transmitter.
5809 Heat
Detector
RF One-piece rate-of-rise heat detector with a built-in transmitter.
5816
5816MN
Door/Window
Transmitters
RF
Has two unique input (loop) codes: one for a wired closed circuit
contact loop; the other for its built-in reed switch (used with a
magnet).
5816TEMP
Low-Temp. Sensor
RF
Transmits a fault condition when temperature drops below 45°F.
Installation Instructions
8-2