Installing the RF Receiver
You can any ADEMCO 5800 Series Wireless Receivers, including:
RF Receiver No. of Zones
5881L/5882L up to 8
5881M/5882M up to 16 (transmitter zone numbers = 9-24; button zone numbers = 49-56)
5883, 6150RF
up to 16 (transmitter zone numbers = 9-24; button zone numbers = 49-56)
1. Set Device Address to “00” as described in its instructions (set all switches to the right, “off” position).
2. Mount the receiver, noting that the RF receiver can detect signals from transmitters within a
nominal range of 200 feet.
3. Connect the receiver's wire harness to the control's keypad terminals. Plug the connector at the
other end of the harness into the receiver. Refer to the installation instructions provided with the
receiver for further installation procedures regarding antenna mounting, etc.
NOTES
•
The receiver is supervised and a trouble report is sent (“CHECK 100” displayed) if communication
between the panel and receiver is interrupted, or if no valid RF signals from at least one supervised
transmitter are received within 12 hours.
If the receiver is mounted remotely:
•
Place the RF receiver in a high, centrally located area for best reception.
•
Do not locate the receiver or transmitters on or near metal objects. This will decrease range and/or
block transmissions.
•
Do not locate the RF receiver in an area of high RF interference (indicated by frequent or prolonged
lighting of the LED in the receiver; random flicker is OK).
•
Do not locate RF receiver closer than 10 feet from any keypads to avoid interference from the
microprocessors in those units.
MOUNTING
HOLES
INTERFERENCE
INDICATOR
LED
CIRCUIT BOARD
DIP
SWITCH
ANTENNAS
(INSERT IN
RIGHT-HAND
TERMINALS)
YELLOW
RED
BLACK
GREEN
WIRING OPENING
KNOCKOUT AREA
FOR SURFACE WIRING
TO CONTROL'S
REMOTE KEYPAD
CONNECTION
POINTS.
5882
LOCATION
TO RELEASE CIRCUIT BOARD,
REMOVE SCREWS AND
BEND BACK TABS
NOTE
CIRCUIT BOARD IS MOUNTED IN
CONTROL'S CABINET. GROUNDING
LUGS (2) PROVIDED
MUST
BE INSERTED
IN LEFT-HAND TERMINALS OF ANTENNA
BLOCKS AND SECURED TO CABINET.
(SEE RECEIVER'S AND CONTROL'S
INSTRUCTIONS)
SOCKET
PLUG
MODEL NO. IS INDICATED ON CIRCUIT BOARD
5881-003-V0
INSERT IN
RIGHT- HAND
TERMINALS
Figure 9. 5881/5882 RF Receiver (cover removed)
Installing a 5800TM Module
1. Mount the 5800TM next to the RF receiver (between one and two feet from the receiver’s
antennas) using its accompanying mounting bracket. Do not install within the control cabinet.
2. Connect the 5800TM to the control panel’s keypad connection terminals as shown on the
Summary of Connections diagram and set to address 28.
NOTES
•
Use this module only if you are using one or more wireless bi-directional keypads or keyfobs with a
wireless Receiver; 5800TM is not necessary if using a Transceiver (e.g., 5883).
•
The 5800TM must be set to address 28 (cut red-W1 jumper).
•
For additional information regarding the 5800TM, refer to the 5800TM’s instructions.