4.
Function
(see also illustration below)
IDENTLOC sensor 1 to 4:
Transmission unit
The transmission unit provides an electromagnetic field for the transmission of energy and data between the evaluation unit
(EU) and the sensor. (For other code carriers, see Chapter 5.4.)
Sensors
Each sensor has an allocated data code that cannot be altered (unique). This codes is permanently queried by the EU via the
transmission unit and evaluated. The code can only be received as long as the sensor is within the transmission range to the
transmission unit.
Teaching mode
In the
of the EU, the codes of all connected sensors are read in and stored. This means, that after every
teaching mode
re-installation or alteration to the sensor, the
must be carried out again.
teaching mode
A stored code is not lost even when the EU is de-energized (non-volatile storage).
Monitoring of opening
The EU permanently compares the received codes of each connected sensor with the correspondingly stored projected value.
1. Identification available
:
Window / door closed
and is correct
2. Identification
:
Window / door open or fault
Message is transmitted to the central
not available or incorrect
control unit.
Lock monitoring
: A contact at the window/door handle is connected parallel to the sensor antenna. Data transmission can
IDENTLOC sensor
only take place, when the window or the door is closed and the handle locked (the contact is then open).
: With multiple locking, the sensor (opening sensor or locking sensor, depending on the type of
IDENTLOC slimline sensors
the connecting rod) is connected to the connecting rod of the locking and thus pushed synchronous with the handlle. Data
transmission can only take place when the window or the door is closed and the handle is locked.
Glass monitoring
(glass breakage sensor and alarm glass sensor)
With passive
the EU differentiates between
and
-
glass breakage sensors,
glass breakage
monitoring of opening.
A corresponding indication is signaled in the EU by the LED that is allocated to the sensor.
The triggering of the glass breakage sensor is
stored in the EU until it is cleared.
-
With an
data transmission is permanently interrupted in case of glass breakage.
alarm glass sensor
-
Automatic line monitoring
The individual code is stored in the sensor housing respectively in the alarm glass adapter. This means that the cable from
the transmission unit to the sensor is automatically monitored on line interruption and short circuit.
Sensor 5:
Standard differential detector group with clear function,
monitoring criterium: 12k1 ±20%.
Status-storing detectors can be used (e.g. passive glass breakage sensors).
Function principle
To control panel
BUS
Energy and data
transmission
Transmission unit 032220.17
Sensor element
Lock monitoring
(only 032 222.17)
Antenna
Antenna and
Identification carrier
IDENTLOC-
Opening sensor
E.g. passive glass breakage
sensor
(for fixed window)
(Direct sensor)
Evaluation unit (EU)
The function of the IDENTLOC-
sensor connections 1 to 4 is
identical.
Both ranges of sensor can be
mixed
for operation.
Sensor 1
Sensor 2
Sensor 3
Sensor 4
Sensor 5: Differential detector group
The transmission unit item no. 032220.17
(or 032235.17 for sensors)
slimline
is required for every sensor.
Energy and
data transmission
IDENTLOC glass breakage
sensor - slimline
Transmission
unit 032235.17
Antenna
Antenna
Passive glass breakage sensor
with identification carrier
Mounting and Connection Instructions IDENTLOC Evaluation Unit
21