Limitations of this System 

 

WARNING!    THE LIMITATIONS OF THIS ALARM SYSTEM

 

 

While this system is an advanced design security system, it does not offer guaranteed protection against burglary 

or other emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to 

warn for a variety of reasons. For example: 

•  Intruders may gain access through unprotected openings or have the technical sophistication to bypass an 

alarm sensor or disconnect an alarm warning device. 

•  Intrusion detectors (e.g. passive infrared detectors), smoke detectors, and many other sensing devices will 

not work without power. Battery operated devices will not work without batteries, with dead batteries, or if the 

batteries are not put in properly. Devices powered solely by AC will not work if their AC power supply is cut off 

for any reason, however briefly. 

•  Signals sent by wireless transmitters may be blocked or reflected by metal before they reach the alarm 

receiver. Even if the signal path has been recently checked during a weekly test, blockage can occur if a 

metal object is moved into the path. 

•  A user may not be able to reach a panic or emergency button quickly enough. 

•  While smoke detectors have played a key role in reducing residential fire deaths in the United States, they 

may not activate or provide early warning for a variety of reasons in as many as 35% of all fires, according to 

data published by the Federal Emergency Management Agency. Some of the reasons smoke detectors used 

in conjunction with this System may not work are as follows. Smoke detectors may have been improperly 

installed and positioned. Smoke detectors may not sense fires that start where smoke cannot reach the 

detectors, such as in chimneys, in walls, or roofs, or on the other side of closed doors. Smoke detectors also 

may not sense a fire on another level of a residence or building. A second floor detector, for example, may not 

sense a first floor or basement fire. Moreover, smoke detectors have sensing limitations. No smoke detector 

can sense every kind of fire every time. In general, detectors may not always warn about fires caused by 

carelessness and safety hazards like smoking in bed, violent explosions, escaping gas, improper storage of 

flammable materials, overloaded electrical circuits, children playing with matches, or arson. Depending upon 

the nature of the fire and/or the locations of the smoke detectors, the detector, even if it operates as 

anticipated, may not provide sufficient warning to allow all occupants to escape in time to prevent injury or 

death. 

•  Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in 

their installation manual. Passive Infrared Detectors do not provide volumetric area protection. They do create 

multiple beams of protection, and intrusion can only be detected in unobstructed areas covered by those 

beams. They cannot detect motion or intrusion that takes place behind walls, ceilings, floors, closed doors, 

glass partitions, glass doors, or windows.  

  Mechanical tampering, masking, painting or spraying of any material on the mirrors, windows or any part of 

the optical system can reduce their detection ability. Passive Infrared Detectors sense changes in 

temperature; however, as the ambient temperature of protected area approaches the temperature range of 

90° to 105°F, the detection performance can decrease. 

•  Alarm warning devices such as sirens, bells or horns may not alert people or wake up sleepers if they are 

located on the other side of closed or partly open doors. If warning devices sound on a different level of the 

residence from the bedrooms, then they are less likely to waken or alert people inside the bedrooms. Even 

persons who are awake may not hear the warning if the alarm is muffled from a stereo, radio, air conditioner 

or other appliance, or by passing traffic. Finally, alarm warning devices, however loud, may not warn hearing-

impaired people or waken deep sleepers. 

•  Telephone lines needed to transmit alarm signals from a premises to a central monitoring station may be out 

of service  or temporarily out of service. Telephone lines are also subject to compromise by sophisticated 

intruders. 

•  Even if the system responds to the emergency as intended, however, occupants may have insufficient time to 

protect themselves from the emergency situation. In the case of a monitored alarm system, authorities may 

not respond appropriately. 

•  This equipment, like other electrical devices, is subject to component failure. Even though this equipment is 

designed to last as long as 10 years, the electronic components could fail at any time. 

The most common cause of an alarm system not functioning when an intrusion or fire occurs is inadequate 

maintenance. This alarm system should be tested weekly to make sure all sensors and transmitters are working 

properly. 

Installing an alarm system may make one eligible for lower insurance rates, but an alarm system is not a 

substitute for insurance. Homeowners, property owners and renters should continue to act prudently in protecting 

themselves and continue to insure their lives and property. 

We continue to develop new and improved protection devices. Users of alarm systems owe it to themselves and 

their loved ones to learn about these developments.

 

Содержание Ademco Vista Series

Страница 1: ...ADEMCO VISTA SERIES VISTA 15P VISTA 15PSIA VISTA 20P VISTA 20PSIA User Guide K5309 1V7C 3 15 Rev C VISTA 15P 15PSIA VISTA 20P 20PSIA...

Страница 2: ...signed for use with devices manufactured or approved by Resideo Technologies Inc through its subsidiary Ademco Inc Resideo for use with your security system Your security system is not designed for us...

Страница 3: ...Arms Perimeter Only Entry Delay Off 13 AWAY Mode Arms Entire System Entry Delay On 13 MAXIMUM Mode Arms Entire System Entry Delay Off 13 Arming Commands 14 Single Button Arming 15 Single Button Step A...

Страница 4: ...ition Arming VISTA 20P 31 Common Zone Operation VISTA 20P 32 Scheduling 33 About Scheduling 33 Creating Schedules 33 Event Logging Procedures 35 About Event Logging 35 Viewing the Event Log 35 Underst...

Страница 5: ...ight Stay Away Instant Maximum STAY arms perimeter zones only and entry delay is on INSTANT same as STAY except entry delay is off NIGHT STAY arms perimeter zones and selected interior zones entry del...

Страница 6: ...ame partition Arming Step Arming and Disarming Burglary Protection The system must be armed before the burglary protection can sense intrusions To arm your system enter your security code followed by...

Страница 7: ...sage Center if Voice Keypad is installed Voice keypads feature a voice message center that lets you record and playback one message The message can be up to 2 5 minutes long The message remains in mem...

Страница 8: ...dicates that an alarm has occurred during your absence and an intruder may still be on the premises LEAVE IMMEDIATELY and CONTACT THE POLICE from a nearby safe location Your keypads are functionally t...

Страница 9: ...e wireless key fobs which can perform various functions programmed by your installer IMPORTANT SECURITY NOTICE Your key fob is similar to your keys or access card If lost or stolen another person can...

Страница 10: ...battery power AC Appears when AC power is present CHIME Appears when the chime feature is activated BAT Low battery condition in a wireless sensor if zone number displayed or low system battery if no...

Страница 11: ...l key depressions must be made within 4 5 seconds of one another If 4 5 seconds elapse without a key depression the entry will be aborted and must be repeated from its beginning Be sure to observe thi...

Страница 12: ...eter portion of burglary system only Interior protection is not armed allowing movement within premises without causing an alarm If pressed twice in succession arms system in Night Stay mode PLAY On V...

Страница 13: ...stem functions 15 MIC On voice keypads microphone for Message Center recordings 16 MESSAGE LED INDICATOR RED On Voice keypads flashes red when message waiting or lights red steady when in record mode...

Страница 14: ...n 2 on VISTA 20P Series only ____________________________________________ Exit Delay seconds Entry Delay 1 seconds Entry Delay 2 seconds Exit Delay Exit delay gives you time to leave through the desig...

Страница 15: ...minimize false alarms sent to the Central Monitoring Station Ask your installer if Exit Alarm is active in your system If so check this box VISTA 20PSIA VISTA 15PSIA The Exit Error condition works th...

Страница 16: ...ghts when all protection zones have been either closed or bypassed 3 Arm the system as desired Alpha Display DISARMED HIT FOR FAULTS Fixed Word Display Zone no and NOT READY Voice Status Voice keypads...

Страница 17: ...s are armed and cause an alarm if anyone enters those areas e g waking in the middle of the night To avoid sounding an alarm you must disarm the system before any activity takes place in those interio...

Страница 18: ...security code 4 MAX same as AWAY described above Note that entry delay is turned off Arming Ding In addition to the keypad beeps the external sounder emits a short ding sound after arming if programm...

Страница 19: ...all perimeter doors and windows 1 Press and hold the assigned function key for 2 seconds no code is required Function keys are shown below Alpha Display DISARMED READY TO ARM Fixed Word Display Green...

Страница 20: ...ee your installer for the meanings of the lit red light Lit Steady system armed AWAY or system armed STAY and exit delay has expired Flashing system armed STAY and exit delay timer active Rapid flashi...

Страница 21: ...ry delay has started you ve opened the entry door you do not need to press the OFF key simply enter your security code The system will disarm in about 15 seconds after the last digit of the code is en...

Страница 22: ...ated The system will not allow fire zones to be bypassed Zones are automatically unbypassed when the system is disarmed 1 6 BYPASS zone number see below Security Code Enter the 2 digit zone number for...

Страница 23: ...a few moments all open zones will be displayed and automatically bypassed Make sure that only those zones that you wish to leave unprotected are bypassed and that there are no other zones unintentiona...

Страница 24: ...ity Code The CHIME message will appear Alpha Display DISARMED CHIME READY TO ARM Fixed Word Display CHIME To turn Chime Mode off 9 CHIME Security Code The CHIME message will disappear Alpha Display DI...

Страница 25: ...check mark in the box beneath that key Setting the Date and Time NOTE All partitions must be disarmed before date time can be set You can set the time and date by doing the following 1 6 3 Master Code...

Страница 26: ...rens Fire Alarm fire alarm temporal pulsing sound at external bells and sirens All panic functions send signals to the Central Monitoring Station if connected To activate a Panic Function Press and ho...

Страница 27: ...macros can be assigned See the chart at the back of this manual for the key s assigned for macros 1 6 6 Master Code Alpha Display DISARMED READY TO ARM 2 Enter the macro number 1 4 for VISTA 20P Seri...

Страница 28: ...Macro Alpha Display MACRO PGM 602F603F 701F2F Function Keystrokes Required Keypad Display 1 Bypass zones 02 03 Press BYPASS 6 key then 2 digit zone number 02 then terminator D then 6 then 2 digit zone...

Страница 29: ...e manually turned on or off using the commands described below See your installer for a list of devices that may be set up for your system A list of these devices is provided at the back of this manua...

Страница 30: ...t to the pager The pager display format is as follows Optional 16 digits 3 digit Event Code AAAAAAAAAAAAAAAA BBB CCCC 1 digit Partition No 3 digit Zone No or User No A B C Optional 16 digits for Accou...

Страница 31: ...for beep then press the pager number 1 4 representing the pager intended to receive the message 2 The recipient on seeing the 999 9999 message will understand the prearranged meaning of this signal I...

Страница 32: ...ost normal user situations Therefore the only step you usually need to do when adding users is assign a user number from the partition s pre assigned user numbers and a security code Authority Level D...

Страница 33: ...en set an access schedule that defines the times this group of users can operate the system The system ignores these users outside the scheduled times User s Partition System Master Code 8 user no 3 0...

Страница 34: ...Partition 1 and Common Zone Armed Partition 2 Only Disarmed Common Zone Only Condition 3 Armed Partition 1 Only Disarmed Partition 2 and Common Zone Disarmed Common Zone Only Condition 4 Armed Partiti...

Страница 35: ...ctive partition number is displayed in the upper left portion of screen if the option is selected Alpha Display 2 DISARMED READY TO ARM Fixed Word Display Green LED lit Multi Partition Arming VISTA 20...

Страница 36: ...s are armed If only one partition is armed the system ignores faults on the common zone Either partition may arm its system if the common zone is faulted but once armed the other partition will not be...

Страница 37: ...for a list of output device numbers used in your system 02 set a user access schedule for one or more users see Security Codes section for an explanation of access groups 03 send a latch key report t...

Страница 38: ...only to event numbers 01 02 and 03 Refer to step 7 for available entries Press to continue STOP SMTWTF S HH MMAM 1000000 9 Enter the desired repeat option 0 no repeat 1 repeat schedule weekly 2 repeat...

Страница 39: ...fied by its corresponding code refer to the code table that follows zone or user number depending on type of event partition in which event occurred time and date of the event s occurrence 3 Pressing...

Страница 40: ...RF Sensor Low battery 393 Clean Me Code Definition 401 R401 Armed AWAY MAXIMUM E401 Disarmed 403 Schedule Arm Disarm AWAY 406 Cancel by User 407 Remote Arm Disarm Downloading 408 Quick Arm AWAY 409 Ke...

Страница 41: ...Open each protected door and window in turn and listen for three beeps from the keypad Identification zone number or zone description of each faulted protection point should appear on the display The...

Страница 42: ...VICE Note A display of CHECK 70 on Alpha Display keypads indicates that the wiring connection to the external sounder is at fault opened or shorted and you should CALL FOR SERVICE See BELL FAILURE on...

Страница 43: ...er or BAT with number displayed 00 is RF keypad zone No Accompanied by a single beep about once every 30 seconds at the keypad Either replace the battery yourself or CALL FOR SERVICE If the battery is...

Страница 44: ...nd back up battery for the system has been interrupted and the system is inoperative CALL FOR SERVICE In The Event Of Telephone Operational Problems In the event of telephone operational problems disc...

Страница 45: ...ansmitter and the portable wireless keypad and displays a low battery message A low battery in a portable wireless keypad is detected as soon as one of its keys is pressed and displayed as 00 Battery...

Страница 46: ...pressing the OFF key the security code is not needed to silence fire alarms To clear the display enter your code and press the OFF key again to clear Memory of Alarm 2 If the Keypad s FIRE display doe...

Страница 47: ...ned for FIRE Emergency A key or key pair may have been assigned for manually initiating a FIRE alarm See the Panic Keys section for key assignments For convenience indicate the key or key pair assigne...

Страница 48: ...re detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows A smoke detector installed outside of each separate sleeping area in th...

Страница 49: ...dows doors stairs and rooftops that can be used to escape Indicate escape routes for each room Keep these routes free from obstruction and post copies of the escape routes in every room 4 Assure that...

Страница 50: ...ay or an alarm is active Also silences sounders Memory of alarm remains until cleared Clear Alarm Memory After disarming enter code again Press OFF 1 key again Keypad beeps rapidly on entry if alarm h...

Страница 51: ...YSTEM WILL AUTOARM WITHIN 10 MINUTES a Opened zone numbers will appear b BAT displayed with zone number of transmitter c No special display TWO SHORT BEEPS Keypad only ARM AWAY or MAXIMUM AWAY is disp...

Страница 52: ...NUTES a Opened Zone identifications will appear b LO BAT displayed with description of transmitter c No special display TWO SHORT BEEPS Keypad only ARM AWAY or MAXIMUM ARMED AWAY or MAXIMUM displayed...

Страница 53: ...that it and the radio or television receiver are on different branch circuits Consult the dealer or an experienced radio TV technician for help INDUSTRY CANADA CLASS B STATEMENT This Class B digital a...

Страница 54: ...normes de protection d exploitation et de s curit des r seaux de t l communications comme le prescrivent les documents concernant les exigences techniques relatives au mat riel terminal Le Minist re...

Страница 55: ...e of LED lighting Arm AWAY steady flash Arm STAY steady flash Function Keys A B C D Comments Single Button Arming Step Arming Paging see Paging chart Time Date Display Macro Key 1 Macro Key 2 Macro Ke...

Страница 56: ...t s system master only 3 part s Security Code enter new code Auth Level 1 level Access Group 2 group RF Zone Number 4 zone no Pager on off 5 0 1 01 installer all installer 1 02 system master all maste...

Страница 57: ...1 46 2 0 1 47 2 0 1 48 2 0 1 49 2 0 1 Authority Levels 0 standard user Partitions 0 clears partition 1 and partition 2 defaults 1 arm only 1 partition 1 and common 2 guest 2 partition 2 and common 3...

Страница 58: ...e on off 04 forced STAY arm 07 display reminder 02 user access 05 forced AWAY arm Repeat Options 0 none 1 repeat weekly 2 repeat every other week 3 repeat every third week 4 repeat every fourth week V...

Страница 59: ...y No VISTA 20P VISTA 15P Other _______________________________________________ circle the appropriate model number Type of Alarm Burglary Fire Both Installed by Serviced by Name Name Address Address B...

Страница 60: ...Attic Basement Living Room Dining Room Hall F BURGLARY DETECTING DEVICE LOCATIONS Front Door Basement Door Rear Door All Exterior Doors 1st Floor Windows All windows Interior locations All Accessible...

Страница 61: ...our local authorized service representative is the person best qualified to service your alarm system Arranging some kind of regular service program with him is advisable Your local service representa...

Страница 62: ...58 NOTES...

Страница 63: ...prevent injury or death Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in their installation manual Passive Infrared Detectors do not provide vol...

Страница 64: ...AGES Any product description whether in writing or made orally by Seller or Seller s agents specifications samples models bulletin drawings diagrams engineering sheets or similar materials used in con...

Отзывы: