44
Fire Alarm System
(Continued)
THIS SECTION APPLIES ONLY TO RESIDENTIAL SYSTEMS
National Fire Protection Association Recommendations
on Smoke Detectors
With regard to the number and placement of smoke/heat detectors, we subscribe to the
recommendations contained in the National Fire Protection Association's National Fire Alarm
Code (NFPA 72) noted below.
Early warning fire detection is best achieved by the installation of fire detection equipment in all
rooms and areas of the household as follows: A smoke detector installed outside of each
separate sleeping area, in the immediate vicinity of the bedrooms and on each additional story
of the family living unit, including basements and excluding crawl spaces and unfinished attics.
In addition, the NFPA recommends that you install heat or smoke detectors in the living room,
dining room, bedroom(s), kitchen, hallway(s), attic, furnace room, utility and storage rooms,
basements and attached garages.