Coolant
(4) left side cover
(8) collars
(5) quick fastener
(9) reserve tank cap
(6) left side cover bolt
(10) air cleaner box cover
(7) seat bolt
Servicing Your Honda
49
4. Add coolant to the reserve tank as require to
bring the coolant level to the UPPER level
mark.
5. Install the reserve tank cap (9).
6. Install the left side cover (4), collars (8), seat
bolt (7) and left side cover bolt (6). Close the
air cleaner box cover (10) and turn the quick
fastener (5) clockwise.
Tighten the seat bolt to the specified torque:
19 lbf·ft (26 N·m, 2.7 kgf·m)
Cooling System Inspection
1. Check the cooling system for leaks (see the
Honda Service Manual for troubleshooting of
leaks).
2. Check the water hoses (1) for cracks,
deterioration, and clamp bands for looseness.
3. Check the radiator mount for looseness.
4. Make sure the siphon hose (2) is connected
and not clogged.
5. Check the radiator fins for clogging.
6. Check the water leakage check hole (3) below
the water pump cover (4) for leakage. Make
sure the hole remains open. If water leaks
through the check hole, the water pump seal is
damaged. If oil leaks through the check hole,
the engine oil seal is damaged. See the Honda
Service Manual or consult your Honda dealer
for replacing the water seal or the engine oil
seal. Both seals should be replaced at the
same time.
(1) water hoses
(2) siphon hose
(3) water leakage check hole
(4) water pump cover
(10)
(5)
(6)
(9)
(4)
(7)
(8)
(1)
(2)
(3)
(4)
Содержание CRF250X 2006
Страница 1: ...2006 Honda CRF250X OWNER S MANUAL COMPETITION HANDBOOK ...
Страница 10: ...6 Motorcycle Safety ...
Страница 16: ...12 Before Riding ...
Страница 26: ...22 Basic Operating Instructions ...
Страница 150: ...146 Taking Care of Unexpected ...
Страница 165: ...Technical Information 161 Wiring Diagram ...
Страница 166: ...162 Technical Information ...
Страница 177: ...Memo 173 ...
Страница 178: ...174 Memo ...
Страница 179: ...Memo 175 ...