TROUBLE SHOOTING
Disconnect the machine from the power supply prior to any checks performed
at the machine itself !
Trouble
Possible cause
Solution
Motor does not
start
No power.
Fuses were blown or breaker
tripped.
Overheating relay tripped.
Check power supply.
Change fuse or re-set breaker.
Re-set relay.
Motor stop
during opera-
tion.
Fuses blown out or breakers tripped.
Overheating relay tripped.
Control circuit malfunction.
Pump blocked by foreign objects.
Change fuse or re-set breaker.
Re-set relay.
Re-set control circuit.
Remove foreign objects.
Pump gives
unstable flow
Pump impeller blocked by foreign
objects.
Insufficient coolant fluid level.
Enter power current not stable.
Remove foreign objects.
Add coolant liquid.
Add power stabilizer behind the
enter power.
Pump in opera-
tion but no
flow
Filterable mesh blocked by foreign
objects.
Low coolant level.
Incorrect rotating direction.
Remove foreign objects.
Add coolant circulating liquid..
Re-check power connection.