Stopping the machine
Normal stopt:
Press the OFF-Button (5).
Only in emergency situation:
By pressing the emergency stop button (3)
17.2.3
Starting/stopping coolant pump; supply coolant
Starting coolant pump:
Press the ON button (6) to start.
Stopping coolant pump
Press the OFF button (7) to start.
Coolant supply:
The coolant supply is regulated by means of the shut-off
valve (8) and directed to the drilling/milling point by means
of the hose (9).
17.2.4
Setting the Spindle Speed
N O T E
Never change the speed until the motor/spindle has come to a complete standstill!
Occasionally the engagement of the spindle is facilitated by briefly pressing the JOG
button.
To set a specific speed, move the two levers
to the position shown in the table.
Example 1: desired speed 95min-1
lever 1 to I and lever 2 to position L
Example 2: desired speed 1600min-1
lever 1 to II and lever 2 to position H.