Rev. 1.20
15
October 28, 2020
BC45B4523
Register Details
Sector 0 – Page 0: Command and Status
• Sector Select Register
This register is used for sector selection.
Address
Bit
7
6
5
4
3
2
1
0
0x00
Name
—
—
—
—
—
—
—
Sector
Type
—
—
—
—
—
—
—
R/W
Reset Value
—
—
—
—
—
—
—
0
Bit 7~1 Unimplemented, read as “0”
Bit 0
Sector
: Define sector for register page control
• Command Register
This register is used for command execution.
Address
Bit
7
6
5
4
3
2
1
0
0x01
Name
Command[7:0]
Type
DY
Reset Value
0
0
0
0
0
0
0
0
Bit 7~0
Command[7
:0]: Commands for the device execution
Code
Command
0x00
Idle
0x1A
Transmit
0x16
Receive
0x1E
Transceive
0x12
CalCRC
0x19
LoadKeyFIFO
0x1C
Authent
0x10
RxFilterTune
0x20
LFOTune
0x21
ADCCalibrate
0x22
CardDetect
0x23
FieldDetect
0x31
ReadSignature
• FIFOData Register
This register is the input and output channel for the 64-byte FIFO.
Address
Bit
7
6
5
4
3
2
1
0
0x02
Name
FIFOData[7:0]
Type
DY
Reset Value
x
x
x
x
x
x
x
x
“x”: Unknown
Bit 7~0
FIFOData[7:0]
: Input and output channel for transmission, reception and key initialization.