LP-Gas System
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
2 0 0 2 N E P T U N E
7 • 207
The
red
LED will flash and the alarm will sound whenever a dangerous
level of propane or methane gas is detected. The detector will continue to
alarm until the gas clears or the
MUTE
switch is pressed.
Procedures to Take During an Alarm:
1. Turn off all gas appliances (stove, heaters, furnace). Extinguish all
flames and smoking material. Evacuate the motorhome, leaving all
doors and windows open.
2. Turn off the primary propane tank valve.
3. Determine and repair the source of the leak. Contact a qualified
service professional if additional repairs are necessary or if the
source of the leak cannot be determined.
WARNING: If the alarm sounds and there is no immediate
danger open all doors and windows to air out the
motorhome. Exit the motorhome and turn off the gas at the
LP tank. Do Not re-enter the motorhome until the alarm
stops sounding. If the alarm sounds again after the gas is
turned back on, turn the gas off. Leave the gas off and con-
tact a qualified service technician to find and repair the
leak. Do not re-enter the motorhome until the problem is
corrected.
Alarm Mute:
Press the
TEST-MUTE
button when the detector is in alarm.
1. The
red
LED will continue flash and the alarm will beep every 30
seconds until the concentration of LP-Gas has dispersed to a safe level.
2. The LED will flash
green
until the end of the MUTE cycle.
3. If dangerous gas levels return before the end of the MUTE cycle
the alarm will beep four times and return to phase 1.
4. After two minutes the detector will return to normal operation
(
solid green
) or resound the alarm if dangerous levels of gas
remain.
Fault Alarm:
Should the microprocessor sense a fault in the gas detector, a fault alarm
will sound twice every 15 seconds. The LED will alternately flash
red
to
green
and the
MUTE
switch will not respond to any command. The gas
detector must be repaired or replaced.
1. Vacuum the dust off the detector cover weekly (more frequently in
dusty locations) using the soft brush attachment of the vacuum.
2. Do not spray cleaning agents or waxes directly onto the front
panel. This action may damage the sensor, cause an alarm or cause
a detector malfunction.
Care
Alarm
Содержание 2002 NEPTUNE
Страница 12: ......
Страница 28: ...General Information 2 0 0 2 N E P T U N E 1 28 NOTES...
Страница 32: ......
Страница 73: ...Driving Safety 2 0 0 2 N E P T U N E 2 73 Rear View VIEWS Front View OM010726 OM010725...
Страница 74: ...Driving Safety 2 0 0 2 N E P T U N E 2 74 Curbside View Roadside View OM010724 OM010723...
Страница 82: ......
Страница 116: ......
Страница 154: ......
Страница 182: ......
Страница 202: ...Water Systems 2 0 0 2 N E P T U N E 6 202 NOTES...
Страница 204: ......
Страница 218: ...LP Gas System 2 0 0 2 N E P T U N E 7 218 NOTES...
Страница 220: ......
Страница 256: ......
Страница 279: ...Electrical Systems Chassis 2 0 0 2 N E P T U N E 9 279 NOTES...
Страница 280: ...Electrical Systems Chassis 2 0 0 2 N E P T U N E 9 280 NOTES...
Страница 282: ......
Страница 331: ...Chassis Information 2 0 0 2 N E P T U N E 10 331 MAINTENANCE RECORD...
Страница 332: ...Chassis Information 2 0 0 2 N E P T U N E 10 332 MAINTENANCE RECORD...
Страница 333: ...Chassis Information 2 0 0 2 N E P T U N E 10 333 MAINTENANCE RECORD...
Страница 336: ......
Страница 337: ...INDEX...
Страница 338: ......