Water Systems
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
2 0 0 2 N E P T U N E
6 • 196
Checking for leaks:
• Back of toilet: check water supply line connection.
• Between closet flange and toilet: Check screws for tightness. If leak
continues, remove toilet and check flange height. Adjust, if neces-
sary to 7/16" above floor. Replace flange seal if damaged.
• Poor flush: A good flush should be obtained within 2 to 3 seconds. If
problem persists remove the water supply line and check flow rate.
The flow rate should be at least ten quarts (9.5 liters) per minute.
• Bowl will not hold water: Check for foreign material in valve blade
groove in the flush drain.
NOTE: Most chemical mixtures for holding tank odor con-
trol are poisonous. Follow the product manufacturer's direc-
tions and warnings when using any holding tank additive.
Sinks, shower and clothes washer drains incorporate a water
trap or "P-trap" and auto vents to prevent waste water hold-
ing tank odor from entering the motorhome. These P-traps
are usually within 54" of a vent tee. These traps must have
water in them to block odors.
During storage water can evaporate and allow odor into
motorhome. If odor is detected run water into sinks, shower
and clothes washer to fill drain traps. The auto vent by
design is to assist in the flow of water in the drain lines by
creating a smooth flow of water in the drain without a vacu-
um.
If the auto vent is stuck in the open position, grey tank
odors may enter the motorhome. Auto vents double as
"clean outs" in case the line has to be “snaked” out.
NOTE: Most chemical mixtures for holding tank odor
control are poisonous. Follow the product manufacturer's
directions and warnings when using any holding tank addi-
tive.
NOTE: During cold weather antifreeze must be added to
the drain traps.
Drain Traps & Auto Vents
OM070152
Содержание 2002 NEPTUNE
Страница 12: ......
Страница 28: ...General Information 2 0 0 2 N E P T U N E 1 28 NOTES...
Страница 32: ......
Страница 73: ...Driving Safety 2 0 0 2 N E P T U N E 2 73 Rear View VIEWS Front View OM010726 OM010725...
Страница 74: ...Driving Safety 2 0 0 2 N E P T U N E 2 74 Curbside View Roadside View OM010724 OM010723...
Страница 82: ......
Страница 116: ......
Страница 154: ......
Страница 182: ......
Страница 202: ...Water Systems 2 0 0 2 N E P T U N E 6 202 NOTES...
Страница 204: ......
Страница 218: ...LP Gas System 2 0 0 2 N E P T U N E 7 218 NOTES...
Страница 220: ......
Страница 256: ......
Страница 279: ...Electrical Systems Chassis 2 0 0 2 N E P T U N E 9 279 NOTES...
Страница 280: ...Electrical Systems Chassis 2 0 0 2 N E P T U N E 9 280 NOTES...
Страница 282: ......
Страница 331: ...Chassis Information 2 0 0 2 N E P T U N E 10 331 MAINTENANCE RECORD...
Страница 332: ...Chassis Information 2 0 0 2 N E P T U N E 10 332 MAINTENANCE RECORD...
Страница 333: ...Chassis Information 2 0 0 2 N E P T U N E 10 333 MAINTENANCE RECORD...
Страница 336: ......
Страница 337: ...INDEX...
Страница 338: ......